Antibody-Based Capture of Target Peptides in Multiple Reaction Monitoring Experiments
Authors:
- 1 January 2015
- book chapter
- Published by Springer Nature
- Vol. 1293, 123-135
Abstract
Targeted quantitative mass spectrometry of immunoaffinity-enriched peptides, termed immuno-multiple reaction monitoring (iMRM), is a powerful method for determining the relative abundance of proteins in complex mixtures, like plasma or whole tissue. This technique combines 1,000-fold enrichment potential of antibodies for target peptides with the selectivity of multiple reaction monitoring mass spectrometry (MRM-MS). Using heavy isotope-labeled peptide counterparts as internal standards ensures high levels of precision. Further, LC-MRM-MS selectivity allows for multiplexing; antibodies recognizing different peptides can be added directly to a single mixture without subjecting to interferences common to other multiple antibody protein assays. Integrated extracted ion chromatograms (XIC) of product ions from endogenous unlabeled “light” peptide and stable isotope-labeled internal standard “heavy” peptides are used to generate a light/heavy peak area ratio. This ratio is proportional to the amount of peptide in the digestion mixture and can be used to estimate the concentration of protein in the sample.Keywords
This publication has 18 references indexed in Scilit:
- Targeted Quantitation of Proteins by Mass SpectrometryBiochemistry, 2013
- Sequential Multiplexed Analyte Quantification Using Peptide Immunoaffinity Enrichment Coupled to Mass SpectrometryMolecular & Cellular Proteomics, 2012
- Interlaboratory Evaluation of Automated, Multiplexed Peptide Immunoaffinity Enrichment Coupled to Multiple Reaction Monitoring Mass Spectrometry for Quantifying Proteins in PlasmaMolecular & Cellular Proteomics, 2012
- Evaluation of Large Scale Quantitative Proteomic Assay Development Using Peptide Affinity-based Mass SpectrometryMolecular & Cellular Proteomics, 2011
- Automated screening of monoclonal antibodies for SISCAPA assays using a magnetic bead processor and liquid chromatography-selected reaction monitoring-mass spectrometryJournal of Immunological Methods, 2009
- Quantification of Cardiovascular Biomarkers in Patient Plasma by Targeted Mass Spectrometry and Stable Isotope DilutionMolecular & Cellular Proteomics, 2009
- Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasmaNature Biotechnology, 2009
- Prediction of high-responding peptides for targeted protein assays by mass spectrometryNature Biotechnology, 2009
- PeptideAtlas: a resource for target selection for emerging targeted proteomics workflowsEMBO Reports, 2008
- Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope DilutionMolecular & Cellular Proteomics, 2007