Treatment of distal unruptured intracranial aneurysms using a surface-modified flow diverter under prasugrel monotherapy: a pilot safety trial
- 25 February 2021
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (7) , 647-651
Abstract
Background Flow diverters (FDs) are effective in the treatment of carotid aneurysms. Compared with carotid aneurysms, the treatment of distal intracranial aneurysms with FDs has been associated with a relatively high incidence of complications. Low thrombogenic modified-surface FDs may reduce ischemic complications and allow for the use of a single antiplatelet medication. The aim of this study was to assess the safety and efficacy of the p48 MW HPC Flow Modulation Device (Phenox GmbH, Bochum, Germany) to treat distal intracranial aneurysms used in combination with prasugrel monotherapy. Methods This was a single-center, prospective, pivotal, open, single-arm study. Patients were included in this study from December 2019 to September 2020. The primary endpoints were the incidence of any neurologic deficit after treatment until 1 month of follow-up, defined as National Institutes of Health Stroke Scale (NIHSS) ≥1, and the incidence of acute ischemic lesions in magnetic resonance imagin (MRI) images 48 hours after treatment. The secondary endpoint was the rate of complete occlusion of the aneurysms at the 1-month follow-up. Results Twenty-one patients harboring 27 distal aneurysms of the anterior circulation were included. Mean age was 57.8 (SD 9.7) years, and 16 patients were female (80%). No patient had neurologic symptoms at the 1-month follow-up. Four patients (20%) had asymptomatic acute brain ischemic lesions on MRI. Complete aneurysm occlusion occurred in 9/27 (33.3%) aneurysms at the 1-month follow-up. Conclusion In this pilot safety trial, treatment of distal intracranial aneurysms with p48 MW HPC under monotherapy with prasugrel appeared to be safe.Keywords
This publication has 33 references indexed in Scilit:
- Middle Cerebral Artery Bifurcation Aneurysms Treated by Extrasaccular Flow Diverters: Midterm Angiographic Evolution and Clinical OutcomeAmerican Journal of Neuroradiology, 2016
- Diffusion-Weighted Imaging–Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-AnalysisAmerican Journal of Neuroradiology, 2016
- Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization DeviceNeurosurgery, 2016
- Flow Diversion in Middle Cerebral Artery Aneurysms: Is It Really an All-Purpose Treatment?World Neurosurgery, 2016
- Flow-Diverter Stents for the Treatment of Saccular Middle Cerebral Artery Bifurcation AneurysmsAmerican Journal of Neuroradiology, 2015
- Pipeline endovascular device for the treatment of intracranial aneurysms at the level of the circle of Willis and beyond: multicenter experienceJournal of NeuroInterventional Surgery, 2014
- Flow Diverters at and Beyond the Level of the Circle of Willis for the Treatment of Intracranial AneurysmsStroke, 2012
- New Brain Lesions After Carotid Stenting Versus Carotid EndarterectomyStroke, 2008
- Silent microemboli related to diagnostic cerebral angiography: a matter of operator’s experience and patient’s diseaseNeuroradiology, 2006
- Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: a prospective studyThe Lancet, 1999