Performance Improvement of Grid-Integrated Doubly Fed Induction Generator under Asymmetrical and Symmetrical Faults
Open Access
Abstract
The doubly fed induction generator (DFIG)-based wind energy conversion system (WECS) suffers from voltage and frequency fluctuations due to the stochastic nature of wind speed as well as nonlinear loads. Moreover, the high penetration of wind energy into the power grid is a challenge for its smooth operation. Hence, symmetrical faults are most intense, inflicting the stator winding to low voltage, disturbing the low-voltage ride-through (LVRT) functionality of a DFIG. The vector control strategy with proportional–integral (PI) controllers was used to control rotor-side converter (RSC) and grid-side converter (GSC) parameters. During a symmetrical fault, however, a series grid-side converter (SGSC) with a shunt injection transformer on the stator side was used to keep the rotor current at an acceptable level in accordance with grid code requirements (GCRs). For the validation of results, the proposed scheme of PI + SGSC is compared with PI and a combination of PI with Dynamic Impedance Fault Current Limiter (DIFCL). The MATLAB simulation results demonstrate that the proposed scheme provides superior performance by providing 77.6% and 20.61% improved performance in rotor current compared to that of PI and PI + DIFCL control schemes for improving the LVRT performance of DFIG.Keywords
This publication has 36 references indexed in Scilit:
- Enhancing fault ride‐through capability of DFIG with modified SMES‐FCL and RSC controlIET Generation, Transmission & Distribution, 2017
- Achieving a 100% Renewable Grid: Operating Electric Power Systems with Extremely High Levels of Variable Renewable EnergyIEEE Power and Energy Magazine, 2017
- Performances analysis of WT-DFIG with PV and fuel cell hybrid power sources system associated with hydrogen storage hybrid energy systemInternational Journal of Hydrogen Energy, 2016
- Technical impacts of high penetration levels of wind power on power system stabilityWires Energy and Environment, 2016
- Solar–wind hybrid renewable energy system: A reviewRenewable and Sustainable Energy Reviews, 2016
- Fault ride-through enhancement using an enhanced field oriented control technique for converters of grid connected DFIG and STATCOM for different types of faultsISA Transactions, 2016
- Scaled Current Tracking Control for Doubly Fed Induction Generator to Ride-Through Serious Grid FaultsIEEE Transactions on Power Electronics, 2015
- Improved Demagnetization Control of a Doubly-Fed Induction Generator Under Balanced Grid FaultIEEE Transactions on Power Electronics, 2014
- LVRT Capability of DFIG-Based WECS Under Asymmetrical Grid Fault ConditionIEEE Transactions on Industrial Electronics, 2012
- Dynamic performance of wind farms with bridge-type superconducting fault current limiter in distribution grid2011