Sequence‐component‐based current differential protection for transmission lines connected with IIGs
Authors:
- 27 April 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (12) , 3086-3096
Abstract
Current differential protection is normally designed as the primary protection for the high‐voltage transmission lines. However, for the transmission line that is connected with the large‐scale inverter‐interfaced generators (IIGs), the performance of the conventional current differential protection is significantly affected by the difference between the sequence components of the fault currents on both sides of this line. This may result in the mal‐operation of protection relays. This study proposes a sequence‐component‐based current differential protection from a suitable fault model of IIGs under positive‐sequence control strategy. A differential coefficient is introduced to overcome the low sensitivity and poor reliability of the conventional differential protection. The proposed scheme discriminates the internal faults accurately from the external faults and the normal operating conditions. Additionally, the robustness analysis shows that this scheme is immune to different fault resistances, fault locations, and system parameters. Simulation results in power systems computer‐aided design/electro‐magnetic transient design and control validate the effectiveness of the proposed sequence‐component‐based protection scheme.Keywords
This publication has 25 references indexed in Scilit:
- Protection of AC and DC distribution systems Embedding distributed energy resources: A comparative review and analysisRenewable and Sustainable Energy Reviews, 2015
- Design and advanced control strategies of a hybrid energy storage system for the grid integration of wind power generationsIET Renewable Power Generation, 2015
- Decision tree‐induced fuzzy rule‐based differential relaying for transmission line including unified power flow controller and wind‐farmsIET Generation, Transmission & Distribution, 2014
- Distance Protection of Lines Emanating From Full-Scale Converter-Interfaced Renewable Energy Power Plants—Part II: Solution Description and EvaluationIEEE Transactions on Power Delivery, 2014
- Distance Protection of Lines Emanating From Full-Scale Converter-Interfaced Renewable Energy Power Plants—Part I: Problem StatementIEEE Transactions on Power Delivery, 2014
- An Impedance Protection Scheme for Feeders of Active Distribution NetworksIEEE Transactions on Power Delivery, 2014
- Time‐frequency transform‐based differential scheme for microgrid protectionIET Generation, Transmission & Distribution, 2014
- Coordination of Overcurrent, Directional and Differential Relays for the Protection of Microgrid SystemProcedia Technology, 2013
- Review of international grid codes for wind power integration: Diversity, technology and a case for global standardRenewable and Sustainable Energy Reviews, 2012
- Design and analysis of active power control strategies for distributed generation inverters under unbalanced grid faultsIET Generation, Transmission & Distribution, 2010