Circuit life span in critically ill children on continuous renal replacement treatment: a prospective observational evaluation study
Open Access
- 25 July 2008
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 12 (4) , R93
Abstract
Introduction: One of the greatest problems with continuous renal replacement therapy (CRRT) is early coagulation of the filters. Few studies have monitored circuit function prospectively. The purpose of this study was to determine the variables associated with circuit life in critically ill children with CRRT. Methods: A prospective observational study was performed in 122 children treated with CRRT in a pediatric intensive care unit from 1996 to 2006. Patient and filter characteristics were analyzed to determine their influence on circuit life. Data were collected on 540 filters in 122 patients and an analysis was performed of the 365 filters (67.6%) that were changed due to circuit coagulation. Results: The median circuit life was 31 hours (range 1 to 293 hours). A univariate and multivariate logistic regression study was performed to assess the influence of each one of the factors on circuit life span. No significant differences in filter life were found according to age, weight, diagnoses, pump, site of venous access, blood flow rate, ultrafiltration rate, inotropic drug support, or patient outcome. The mean circuit life span was longer when the heparin dose was greater than 20 U/kg per hour (39 versus 29.1 hours; P = 0.008), with hemodiafiltration compared with hemofiltration (34 versus 22.7 hours; P = 0.001), with filters with surface areas of 0.4 to 0.9 m2 (38.2 versus 26.1 hours; P = 0.01), and with a catheter size of 6.5 French or greater (33.0 versus 25.0 hours; P = 0.04). In the multivariate analysis, hemodiafiltration, heparin dose of greater than 20 U/kg per hour, filter surface area of 0.4 m2 or greater, and initial creatinine of less than 2 mg/dL were associated with a filter life of more than 24 and 48 hours. Total effluent rate of greater than 35 mL/kg per hour was associated only with a filter life of more than 24 hours. Conclusion: Circuit life span in CRRT in children is short but may be increased by the use of hemodiafiltration, higher heparin doses, and filters with a high surface area.Keywords
This publication has 29 references indexed in Scilit:
- Continuous renal replacement therapy: A worldwide practice surveyIntensive Care Medicine, 2007
- Clinical review: Patency of the circuit in continuous renal replacement therapyCritical Care, 2007
- Prognosis in critically ill children requiring continuous renal replacement therapyPediatric Nephrology, 2005
- Renal replacement therapy in pediatric critical care medicineCurrent Opinion in Pediatrics, 2005
- Pediatric patients with multi-organ dysfunction syndrome receiving continuous renal replacement therapyKidney International, 2005
- Blood flow reductions during continuous renal replacement therapy and circuit lifeIntensive Care Medicine, 2004
- Pre-Dilution vs. Post-Dilution during Continuous Veno-Venous Hemofiltration: Impact on Filter Life and Azotemic ControlNephron Clinical Practice, 2003
- Outcome in Children Receiving Continuous Venovenous HemofiltrationPediatrics, 2001
- Transfusion requirements during continuous veno-venous haemofiltration: – the importance of filter lifeIntensive Care Medicine, 2000
- Continuous Renal Replacement Therapy in Critically Ill Patients: Monitoring Circuit FunctionAnaesthesia and Intensive Care, 1996