PurposeThe purpose is to assess the performance of a pre-trained deep learning model in the task of classifying between coronavirus disease (COVID)-positive and COVID-negative patients from chest radiographs (CXRs) while considering various image acquisition parameters, clinical factors, and patient demographics.MethodsStandard and soft-tissue CXRs of 9860 patients comprised the “original dataset,” consisting of training and test sets and were used to train a DenseNet-121 architecture model to classify COVID-19 using three classification algorithms: standard, soft tissue, and a combination of both types of images via feature fusion. A larger more-current test set of 5893 patients (the “current test set”) was used to assess the performance of the pretrained model. The current test set contained a larger span of dates, incorporated different variants of the virus and included different immunization statuses. Model performance between the original and current test sets was evaluated using area under the receiver operating characteristic curve (ROC AUC) [95% CI].ResultsThe model achieved AUC values of 0.67 [0.65, 0.70] for cropped standard images, 0.65 [0.63, 0.67] for cropped soft-tissue images, and 0.67 [0.65, 0.69] for both types of cropped images. These were all significantly lower than the performance of the model on the original test set. Investigations regarding matching the acquisition dates between the test sets (i.e., controlling for virus variants), immunization status, disease severity, and age and sex distributions did not fully explain the discrepancy in performance.ConclusionsSeveral relevant factors were considered to determine whether differences existed in the test sets, including time period of image acquisition, vaccination status, and disease severity. The lower performance on the current test set may have occurred due to model overfitting and a lack of generalizability.Keywords
Funding Information
- National Institutes of Health (S10 OD025081)
- National Institutes of Health (75N92020C00008)
- National Institutes of Health (75N92020C00021)
This publication has 31 references indexed in Scilit:
- COVID-19 on Chest Radiographs: A Multireader Evaluation of an Artificial Intelligence SystemRadiology, 2020
- Frequency and Distribution of Chest Radiographic Findings in Patients Positive for COVID-19Radiology, 2020
- Automated Assessment and Tracking of COVID-19 Pulmonary Disease Severity on Chest Radiographs Using Convolutional Siamese Neural NetworksRadiology: Artificial Intelligence, 2020
- Clinically Applicable AI System for Accurate Diagnosis, Quantitative Measurements, and Prognosis of COVID-19 Pneumonia Using Computed TomographyCell, 2020
- Imaging Profile of the COVID-19 Infection: Radiologic Findings and Literature ReviewRadiology: Cardiothoracic Imaging, 2020
- Deep learning for chest radiograph diagnosis: A retrospective comparison of the CheXNeXt algorithm to practicing radiologistsPLOS Medicine, 2018
- Severity scoring of lung oedema on the chest radiograph is associated with clinical outcomes in ARDSThorax, 2018
- Two public chest X-ray datasets for computer-aided screening of pulmonary diseases2014
- “Proper” Binormal ROC Curves: Theory and Maximum-Likelihood EstimationJournal of Mathematical Psychology, 1999
- Comparing the Areas under Two or More Correlated Receiver Operating Characteristic Curves: A Nonparametric ApproachBiometrics, 1988