Synthetic Receptors Decorated on Nanoparticles for Selective and Sensitive Glyphosate Detection
Authors:
Open Access
- 30 January 2025
- journal article
- research article
- Published by Tsinghua University Press in Photonic Sensors
- Vol. 15 (3) , 1-17
Abstract
Herein, an innovative glyphosate imprinted poly(hydroxyethyl methacrylate-N-methacroyl-(L)-phenylalanine methyl ester nanoparticles (MIP@NPs) based plasmonic nanosensor featured with high sensitivity and selectivity was constructed by using the molecular imprinting technique and used for real-time glyphosate detection. The characterization of nanoparticles was performed by the nano Zetasizer and scanning electron microscopy (SEM), while nanosensors were characterized by the Fourier transform infrared-attenuated total reflection (FTIR-ATR) and contact angle measurement. Control experiments were conducted to evaluate the imprinting efficiency on the signal response using a non-imprinted surface plasmon resonance (NIP SPR) nanosensor prepared without adding glyphosate pesticide into the polymerization mixture. The MIP@NPs integrated molecularly imprinted surface plasmon resonance (MIP SPR) nanosensor having synthetic molecular recognition elements yielded a novel biosensing platform for label-free detection and real-time monitoring of glyphosate pesticide. The MIP SPR nanosensor detected the target glyphosate molecule 4.950 times more selectively than the competitor molecule malathion while 3.918 times more selectively than the competitor molecule malaoxon. In addition, the imprinting efficiency factor was found to be 6.76, indicating that the molecular imprinting process was successful. In addition, the imprinting factor was found to be 6.76. Kinetic studies and adsorption characteristics of glycosate adsorption were carried out to assess adsorption dynamics. The linear concentration range for glyphosate detection was 0.001 ppm–10.000 ppm of pesticide, and the detection limit was found to be 0.120 ppb. Studies on the repeatability of the MIP SPR nanosensor revealed that even after five cycles, the signal response for glyphosate detection did not change significantly with relative standard deviation, RSD<1.5 value. The artificial urine selected as the real sample was spiked with glyphosate at a final concentration of 10.000 ppm to evaluate the matrix effect, and the glyphosate amount was reported.Keywords
This publication has 57 references indexed in Scilit:
- Graphene/Au/MIP-Coated D-Shaped Optical Fiber–Based SPR Sensor for Ethanol DetectionPlasmonics, 2023
- Development of Molecularly Imprinted Polymer‐Based Optical Sensor for the Sensitive Penicillin G Detection in MilkChemistrySelect, 2021
- Glyphosate concentrations in global freshwaters: are aquatic organisms at risk?Environmental Science and Pollution Research, 2021
- Electrochemical Sensor Based on Reduced Graphene Oxide/Double-Walled Carbon Nanotubes/Octahedral Fe3O4/Chitosan Composite for Glyphosate DetectionBulletin of Environmental Contamination and Toxicology, 2021
- A Water‐Gated Organic Thin‐Film Transistor for Glyphosate Detection: A Comparative Study with Fluorescence SensingChemistry – A European Journal, 2020
- Glyphosate detection: methods, needs and challengesEnvironmental Chemistry Letters, 2018
- Non-point source pollution of glyphosate and AMPA in a rural basin from the southeast Pampas, ArgentinaEnvironmental Science and Pollution Research, 2018
- Analysis of glyphosate and aminomethylphosphonic acid in water, plant materials and soilPest Management Science, 2015
- Assessment of soybean injury from glyphosate using airborne multispectral remote sensingPest Management Science, 2014
- Present and future of surface plasmon resonance biosensorsAnalytical and Bioanalytical Chemistry, 2003