Three dimensional validation of an instrumented handrail for stair gait
Authors:
- 7 October 2020
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 86 (1) , 16-19
Abstract
Some studies have used load cells (LC) to measure the force applied to horizontal handrails, but no work has validated an inclined set-up that can be used to bring new insights into handrail use during staircase gait. The aim of this study was to validate the accuracy of an inclined handrail set-up instrumented with LC. A handrail set-up designed to be easily reconstructed and integrating two commercial LC is proposed. Twenty points were tested along the handrail, with four reference weights in the three orthogonal directions of the sensors (Medio-Lateral, Antero-Posterior, Vertical). For each direction, the percentage (%) of error and the cross-talk between the known and recorded forces were calculated. A linear regression of the % error was performed to evaluate measurement accuracy in relation to point of application along the handrail. The current easily replicated set-up of an inclined handrail showed accurate measures with low cross-talk. The percentage of error and cross-talk were below 3.7% and 3.7%, respectively, consistent with previous studies evaluating inclined handrail with other methods. The error and cross-talk were greater in the Medio-Lateral and Antero-Posterior directions. The error in the Antero-Posterior direction was larger over the upper part of the handrail.Keywords
Funding Information
- Canada Foundation for Innovation
This publication has 9 references indexed in Scilit:
- Influence of handrail height and fall direction on center of mass control and the physical demands of reach-to-grasp balance recovery reactionsGait & Posture, 2018
- A novel method for synchronizing motion capture with other data sources for millisecond-level precisionGait & Posture, 2017
- A review of stairway falls and stair negotiation: Lessons learned and future needs to reduce injuryGait & Posture, 2016
- Kinematic and Kinetic Evaluation of the Stance Phase of Stair Ambulation in Persons with Stroke and Healthy Adults: A Pilot StudyJournal of Applied Biomechanics, 2013
- Climbing Stairs After Outpatient Rehabilitation for a Lower-Limb AmputationArchives of Physical Medicine and Rehabilitation, 2013
- Relationship between stair ambulation with and without a handrail and centre of pressure velocities during stair ascent and descentGait & Posture, 2011
- Influence of light handrail use on the biomechanics of stair negotiation in old ageGait & Posture, 2008
- Instrumented staircase for kinetic analyses of upper-and lower-limb function during stair gaitMedical & Biological Engineering & Computing, 2005
- Rail supporting transducer posts for three-dimensional force measurementIEEE Transactions on Rehabilitation Engineering, 1997