Purpose To investigate ASL-MRI features of flow-diverted aneurysms, review their haemodynamic surrogates, and discuss their pertinent clinical implications. Methods Retrospective single institutional analysis was performed on the clinical and imaging data of patients who underwent digital subtraction angiography (DSA) and ASL-MRI after endovascular flow diversion for cerebral aneurysms. Pseudo-continuous ASL-MRI was performed with post-label delays of 1525–1800 ms. Intra-aneurysmal “trapped labelled spins” (TLS)-related hypersignal, as seen on cerebral blood flow (CBF)-weighted maps of ASL-MRI, was investigated. Intermodality equivalence with DSA [O'Kelly-Marotta (OKM) grading for occlusion], 3D-TOF-MRA, and 3D spin-echo T1-weighted (“black-blood”) images was assessed. Results Ten cases were included. “TLS” signal was demonstrable in 7/8 (87.5%) of the DSA-visible flow-diverted aneurysms (OKM grade B3, n = 6; OKM grade A3, n = 2). No TLS was seen in both OKM-D (excluded) aneurysms. TLS was not visualised in an OKM-B3 aneurysm with < 3 mm opacifying remnant. 3D-TOF-MRA and ASL-MRI were discordant at 5 instances (45.4%; TOF-MRA false negative, n = 4; false positive, n = 1). Loss of flow void on black-blood images corresponded to the absence of TLS and vice versa in all cases but one. Conclusion “Trapped labelled spins”-related signal on ASL-MRI occurs in patent large aneurysms that have undergone successful endovascular flow diversion. This phenomenon likely represents an interplay of a multitude of haemodynamic factors including decelerated intra-aneurysmal inflow and outflow restriction. Serial intra-saccular TLS signal changes may hold diagnostic value, including contexts where 3D-TOF-MRA interpretation becomes dubious. “Trapped labelled spins”-related signal as a non-invasive proxy marker of aneurysm patency can possibly obviate unnecessary DSA.Keywords
This publication has 38 references indexed in Scilit:
- Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular AneurysmsStroke, 2013
- Endovascular Treatment of Intracranial Aneurysms With Flow DivertersStroke, 2013
- Simple Measurement of Aneurysm Residual after Treatment: the SMART scale for evaluation of intracranial aneurysms treated with flow divertersActa Neurochirurgica, 2011
- Arterial Spin Label Imaging of Acute Ischemic Stroke and Transient Ischemic AttackNeuroimaging Clinics Of North America, 2011
- Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion TreatmentAmerican Journal of Neuroradiology, 2010
- Endoluminal Scaffolds for Vascular Reconstruction and Exclusion of Aneurysms From the Cerebral CirculationStroke, 2010
- Arterial Spin Labeling Perfusion MRI at Multiple Delay Times: A Correlative Study with H215O Positron Emission Tomography in Patients with Symptomatic Carotid Artery OcclusionJournal of Cerebral Blood Flow & Metabolism, 2009
- An Original Flow Diversion Device for the Treatment of Intracranial AneurysmsStroke, 2009
- In Vitro Evaluation of Flow Divertors in an Elastase-Induced Saccular Aneurysm Model in RabbitJournal of Biomechanical Engineering, 2007
- Three-Dimensional Time-of-Flight MR Angiography in the Evaluation of Cerebral AneurysmsJournal of Computer Assisted Tomography, 1990