Radiometric Cross-Calibration of Hyperspectral Microsatellites Using Spectral Homogeneity Factor
Open Access
- 2 December 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 18 (19391404) , 2342-2354
Abstract
On-orbit radiometric calibration is essential for the quantitative use of hyperspectral satellite and sensor monitoring, but its frequency is constrained by available calibration sites, especially for microsatellites with limited imaging capabilities. To reduce dependence on specific sites for on-orbit radiometric calibration, this article introduces a cross-calibration method that uses spectral homogeneity factor (SpecHF) to select targets in open fields. Initially, utilizing hyperspectral images from the advanced hyperspectral imager on board the Gaofen-5B satellite, we developed the SpecHF and selected calibration targets in the Ulanbuh Desert, Inner Mongolia, China. Then, the cross-calibration of the Compact Continuous Tunable LVF-based Hyperspectral Imager on board the microsatellite QMX-1 and the well-calibrated orbita hyperspectral sensor carried by the Zhuhai-1 satellite was performed on 10 September 2022. The intrinsic offsets between two sensors caused by spectral response functions (SRFs) mismatches were compensated using the spectral band adjustment factor, which accounts for the target's spectral profile and the SRF of both sensors. The comparison of the cross-calibrated top-of-atmosphere reflectance from Q1C with datasets from the radiometric calibration network revealed high consistency, with a root-mean-square error of 0.032. Additionally, a ground simultaneous validation conducted in Wuxi, China, on 31 December 2022, demonstrated the high accuracy and effective performance of the cross-calibration results in real-world settings, achieving an average MAE of 0.009. The results show that SpecHF-selected spectral homogeneous targets are well-suited for on-orbit radiometric cross-calibration. By overcoming site limitations, this method provides a viable solution for facilitating the flexibility of on-orbit calibration.Keywords
Funding Information
- Startup Research Fund of Henan Academy of Sciences
- Fundamental Research Funds for the Central Universities, China (242025005, 2042022dx0001)
This publication has 32 references indexed in Scilit:
- Validation and analysis of Terra and Aqua MODIS, and SNPP VIIRS vegetation indices under zero vegetation conditions: A case study using Railroad Valley PlayaRemote Sensing of Environment, 2021
- Impacts of dust aerosol and adjacency effects on the accuracy of Landsat 8 and RapidEye surface reflectancesRemote Sensing of Environment, 2017
- Radiometric cross-calibration of Gaofen-1 WFV cameras using Landsat-8 OLI images: A solution for large view angle associated problemsRemote Sensing of Environment, 2016
- Impact of spatial, spectral, and radiometric properties of multispectral imagers on glacier surface classificationRemote Sensing of Environment, 2014
- Forty-year calibrated record of earth-reflected radiance from Landsat: A reviewRemote Sensing of Environment, 2012
- An improved high-resolution solar reference spectrum for earth's atmosphere measurements in the ultraviolet, visible, and near infraredJournal of Quantitative Spectroscopy and Radiative Transfer, 2010
- Impacts of spectral band difference effects on radiometric cross-calibration between satellite sensors in the solar-reflective spectral domainRemote Sensing of Environment, 2007
- A generalized approach to the vicarious calibration of multiple Earth observation sensors using hyperspectral dataRemote Sensing of Environment, 2001
- Selection and characterization of Saharan and Arabian desert sites for the calibration of optical satellite sensorsRemote Sensing of Environment, 1996
- Calibration of NOAA-7 AVHRR, GOES-5, and GOES-6 VISSR/VAS solar channelsRemote Sensing of Environment, 1987