Short-Term Outcomes of Uncemented Bipolar Hemiarthroplasty Using Stainless Steel Fully Hydroxyapatite-Coated Stem in Transcervical Fracture of the Femur
- 8 July 2023
- journal article
- research article
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 57 (8) , 1302-1310
Abstract
Background Bipolar hemiarthroplasty is the standard of care for transcervical fracture in the elderly. Stainless steel being cheaper is preferred over titanium in developing nations for implants and prostheses. This study was conducted for assessing the short-term outcomes of uncemented bipolar hemiarthroplasty done using hydroxyapatite-coated stainless steel prosthesis. Methods Sixty-five patients, >60 year of age operated between 2018 and 2020 at tertiary care centre with stainless steel (316L) completely coated with hydroxyapatite bipolar hemiarthroplasty implants were retrospectively followed up. Radiological outcomes were assessed based on pedestal formation, stem position, radiological limb length discrepancy, sinkage of stem, spot welds and stress shielding. Clinical and functional outcomes were assessed based on mean Harris Hip score. Results Mean Harris Hip score at baseline, 3-week follow-up, 6-week follow-up, 3-month follow-up and 1-year follow-up was 45.9 (SD 2.5), 63.2 (SD 6.5), 75.1 (SD 9.9), 83.9 (SD 9.8) and 87.1 (SD 9.9), respectively. Excellent, good, fair, poor results were seen in 32.31, 40, 18.46, 9.23 of the patients, respectively. Valgus, central and varus stem position was seen in 49.23, 40, 10.77 percent of the patients, respectively. Pedestal formation, radiological limb length discrepancy, sinkage, spot welds, stress shielding was seen in 6.15, 32.31, 3.07, 53.85, 40 percent of the patients, respectively. Conclusion Short-term outcomes of this study provides evidence that using a more affordable fully hydroxyapatite-coated stainless steel prosthesis for uncemented bipolar hemiarthroplasty is an appropriate treatment option for the transcervical femur fracture.Keywords
This publication has 16 references indexed in Scilit:
- Evaluating the effects of hydroxyapatite coating on the corrosion behavior of severely deformed 316Ti SS for surgical implantsMaterials Science and Engineering: C, 2015
- Cementless bipolar hemiarthroplasty in femoral neck fractures in elderlyIndian Journal of Orthopaedics, 2011
- Cemented versus Uncemented Hemiarthroplasty for Displaced Femoral Neck FracturesClinical Orthopaedics and Related Research, 2009
- Outcome after femoral neck fractures: A comparison of Harris Hip Score, Eq-5d and Barthel IndexInjury, 2008
- A randomised controlled trial comparing bipolar hemiarthroplasty with total hip replacement for displaced intracapsular fractures of the femoral neck in elderly patientsThe Journal of Bone and Joint Surgery. British volume, 2007
- Functional outcome of fracture neck of femur treated with total hip replacement versus bipolar arthroplasty in a South Asian populationArchives of orthopaedic and trauma surgery, 2006
- Cementless bipolar hemiarthroplasty for displaced femoral neck fractures in the elderlyThe Journal of Arthroplasty, 2004
- Transcervical Fractures of the Hip Treated With the Bateman Bipolar ProsthesisClinical Orthopaedics and Related Research, 1990
- Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates.1987
- The rate of bone ingrowth into porous metalJournal of Biomedical Materials Research, 1976