Effect of temperature on the photoproperties of luminescent terbium sensors for homogeneous bioassays
Authors:
- 16 February 2012
- journal article
- research article
- Published by Wiley in Luminescence
- Vol. 28 (2) , 156-161
Abstract
We developed a luminescent terbium sensor (LTS) based on energy resonance transfer for homogeneous bioassays. The effect of temperature on photoluminescence and time‐resolved fluorescence of the LTS was investigated. When the temperature was increased from 277 K to 369 K, the photoluminescence quantum yield decreased by up to 25 %, time‐resolved fluorescence decreased by up to 54 %, and the lifetime shortened dramatically. Studies showed that both photoluminescence and time‐resolved fluorescence quantum yields were largely recovered after samples were heated from 298 to 310, 333 or 369 K and subsequently cooled to 298 K. These results indicate that the homogeneous bioassay with LTS is sensitive to temperature and should be conducted at a constant temperature to ensure the temperature effect does not influence data and to increase the accuracy of the results. The results of this study are important for LTS applications in homogeneous bioassays. Copyright © 2012 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Eu(III) Complexes of Functionalized Octadentate 1-Hydroxypyridin-2-ones: Stability, Bioconjugation, and Luminescence Resonance Energy Transfer StudiesInorganic Chemistry, 2010
- A New Simple Cell-Based Homogeneous Time-Resolved Fluorescence QRET Technique for Receptor-Ligand Interaction ScreeningSLAS Discovery, 2009
- Terbium(III) Chelate as an Efficient Donor for Multiple-Wavelength Fluorescent AcceptorsJournal of Fluorescence, 2008
- Evaluation of Assay Technologies for the Identification of Protein–Peptide Interaction AntagonistsASSAY and Drug Development Technologies, 2007
- The Expanded Octarepeat Domain Selectively Binds Prions and Disrupts Homomeric Prion Protein InteractionsJournal of Biological Chemistry, 2006
- Quantitative Proteomics of the Thyroid Hormone Receptor-Coregulator InteractionsJournal of Biological Chemistry, 2004
- Homogeneous Time-Resolved Fluorescence Quenching Assay (LANCE) for Caspase-3 ,SLAS Discovery, 2002
- A Homogenous 384-Well High Throughput Screen for Novel Tumor Necrosis Factor Receptor: Ligand Interactions Using Time Resolved Energy TransferSLAS Discovery, 1999
- Amine-Reactive Forms of a Luminescent Diethylenetriaminepentaacetic Acid Chelate of Terbium and Europium: Attachment to DNA and Energy Transfer MeasurementsBioconjugate Chemistry, 1997
- Luminescence energy transfer using a terbium chelate: improvements on fluorescence energy transfer.Proceedings of the National Academy of Sciences, 1994