High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples
Authors:
- Stefan StürupSSStefan Stürup
- Henning DahlgaardHDHenning Dahlgaard
- Steffen Chen NielsenSNSteffen Chen Nielsen
- 1 January 1998
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 13 (12) , 1321-1326
Abstract
A high resolution inductively coupled plasma mass spectrometric (HR-ICP-MS) method for the determination of plutonium isotopes and the 240 Pu/ 239 Pu isotope ratio utilising ultrasonic nebulisation was developed. Total plutonium concentrations ( 239+240 Pu) measured in environmental samples by this HR-ICP-MS method were in good agreement with data obtained from α-spectrometry. Quantification was performed by both external calibration and isotope dilution and the best agreement was found by applying isotope dilution. Detection limits of 5, 1 and 1 fg ml –1 were found for 239 Pu, 240 Pu and 242 Pu, respectively. These represent total amounts of 50, 10 and 10 fg or 0.1, 0.08 and 0.002 mBq of the three isotopes in a 10 ml sample volume. The precision (RSD) on the measurement of the 240 Pu/ 239 Pu ratio in environmental samples was approximately 2%, which is close to the theoretical precision (Poisson statistics). The influence of dwell time, number of sweeps and sample uptake rate on the measurement precision of the 240 Pu/ 239 Pu isotope ratio was investigated and the parameters were optimised using a 2 3 experimental design (a central composite design followed by a ridge analysis). The accuracy of the isotope ratio measurement was evaluated by comparing results from this HR-ICP-MS method with results from high resolution α-spectrometry and spectral deconvolution. Good agreement was found between the two techniques.Keywords
This publication has 16 references indexed in Scilit:
- Procedures to define Pu isotopic ratios characterizing a contaminated area in Palomares (Spain)Journal of Radioanalytical and Nuclear Chemistry, 1997
- Identification of the contamination source of plutonium in environmental samples with isotopic ratios determined by inductively coupled plasma mass spectrometry and alpha-spectrometryJournal of Radioanalytical and Nuclear Chemistry, 1997
- Measurements of44Ca:43Ca and42Ca:43Ca Isotope Ratios in Urine Using High Resolution Inductively Coupled Plasma Mass SpectrometryJournal of Analytical Atomic Spectrometry, 1997
- Development of a high-sensitivity inductively coupled plasma mass spectrometer for actinide measurement in the femtogram rangeJournal of Analytical Atomic Spectrometry, 1996
- Investigations for isobaric interference of 238Pu at 238U during thermal ionization mass spectrometry of uranium and plutonium from the same filament loadingInternational Journal of Mass Spectrometry and Ion Processes, 1995
- The measurement of the isotopic composition of plutonium in an Irish Sea sediment by mass spectrometryJournal of Radioanalytical and Nuclear Chemistry, 1995
- Simultaneous analysis of uranium and plutonium using thermal ionization mass spectrometryJournal of Radioanalytical and Nuclear Chemistry, 1995
- Environmental Monitoring of Hanford Nuclear Facility Effluents by Thermal Ionization Mass SpectrometryApplied Spectroscopy, 1994
- Determination of plutonium in environmental samples by controlled valence in aniion exchangeJournal of Radioanalytical and Nuclear Chemistry, 1993
- Radiochemical determination of plutonium in environmental and biological samples by ion exchangeAnalytical Chemistry, 1971