Legionella pneumophila in residential water supplies: environmental surveillance with clinical assessment for Legionnaires' disease.
Authors:
- V L YuVYV L Yu
- Y C YeeYYY C Yee
- S VaccarelloSVS Vaccarello
- W DivenWDW Diven
- T C LeeTLT C Lee
- 1 August 1992
- journal article
- Vol. 109 (1) , 49-57
Abstract
Although cases of community-acquired Legionnaires' disease have been epidemiologically linked to residential water supplies, the risk of acquiring Legionnaires' disease from exposure to Legionella pneumophila in residential water systems is uncertain. The residential water supplies of 218 members of the American Legion in six different geographical areas in Pittsburgh were cultured for L. pneumophila. Residents of the homes provided a recent medical history and a blood sample for detection of antibodies to legionella. A urine sample for legionella urinary antigen testing was also requested from individuals residing in legionella-positive homes and individuals with a positive antibody test. Six percent (14/218) of the homes yielded L. pneumophila (range within six areas 0-22%). Lower hot water tank temperature was significantly associated with legionella positivity (P less than 0.01). Analysis of water samples for mineral content showed no association between legionella positivity and concentrations of calcium and magnesium. Water samples from the area where 22% of the homes surveyed were positive for legionella had a higher iron content than water samples from the other areas tested. None of the individuals residing in legionella-positive homes showed elevated antibody titres to legionella or the presence of legionella antigen in urine. For the immunocompetent hosts, the risk of contracting Legionnaires' disease from exposure to contaminated household water supplies in the Pittsburgh area appears to be low.Keywords
This publication has 27 references indexed in Scilit:
- New and Emerging Etiologies for Community-Acquired Pneumonia with Implications for TherapyMedicine, 1990
- Comparison of Molecular Methods for Subtyping Patients and Epidemiologically Linked Environmental Isolates of Legionella pneumophilaThe Journal of Infectious Diseases, 1988
- Factors Predisposing to Legionella pneumophila Colonization in Residential Water SystemsArchives of Environmental Health: An International Journal, 1988
- Legionnaires' DiseaseThe Annals of Thoracic Surgery, 1987
- NOSOCOMIAL LEGIONELLOSIS IN SURGICAL PATIENTS WITH HEAD-AND-NECK CANCER: IMPLICATIONS FOR EPIDEMIOLOGICAL RESERVOIR AND MODE OF TRANSMISSIONThe Lancet, 1985
- Legionella pneumophilaserogroup 1 subgrouping by monoclonal antibodies – an epidemiological toolEpidemiology and Infection, 1985
- LEGIONELLA PNEUMOPHILA IN WATER PLUMBING SYSTEMSThe Lancet, 1982
- Ubiquitousness ofLegionella pneumophilain the Water Supply of a Hospital with Endemic Legionnaires' DiseaseNew England Journal of Medicine, 1982
- INVESTIGATION AND CONTROL OF AN OUTBREAK OF LEGIONNAIRES' DISEASE IN A DISTRICT GENERAL HOSPITALThe Lancet, 1981
- LEGIONNAIRES' DISEASE IN A TRANSPLANT UNIT: ISOLATION OF THE CAUSATIVE AGENT FROM SHOWER BATHSThe Lancet, 1980