Fast Electromigration Immortality Analysis for Multisegment Copper Interconnect Wires
- 2 February 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 37 (12) , 3137-3150
Abstract
In this article, we present a novel and fast electromigration (EM) immortality check for general multi-segment interconnect wires. Instead of using current density as the key parameter, as in traditional EM analysis methods based on Black’s equation and the Blech limit, the new method estimates the EM-induced steady-state stress in general multi-segment copper interconnect wires based on a novel parameter, Critical EM Voltage, VCrit,EM. We show that the VCrit,EM is essentially the natural, but important, extension of the Blech limit concept, which describes the EM immortality condition for a single segment wire, to more general multi-segment interconnect wires. The proposed method, called voltage-based EM or VBEM method, mitigates the problem of current-density-based EM criteria, which can only be applied to a single wire. The new VBEM method can naturally comprehend the impact of the topology of the wire structure on EM-induced stress. As a result, this new VBEM analysis method is very amenable to addressing EM violations, as it brings new optimization capabilities to the physical design flow. The VBEM stress estimation method is based on the fundamental steady-state stress equations. This approach avoids computationally-intensive numerical methods and can be implemented in CAD tools very easily, as we demonstrate on real design examples. We also show that the proposed VBEM analysis method agrees with results from the finite difference method in the steady state through one example and also agrees with one published closed-form expression of steady-state stress for a special 3-terminal wire case. Furthermore, we compare VBEM against the COMSOL finite element analysis tool and another published EM numerical simulator XSim, validated by measured results, which shows that VBEM agrees with both of them very well in terms of accuracy and thus further validates the proposed method. We also study the impact of current crowding in practical interconnect wires on the estimated steady-state stress, which are shown to be not significant if the length of the wire is much greater than its width. An extension of the VBEM method to consider the significant current crowding effects is also shown and additionally, we analyze mesh-structured interconnect wires and demonstrate that the proposed VBEM method is correct and accurate on such structures.Keywords
Funding Information
- National Science Foundation (CCF-1527324)
- DARPA (HR0011-16-2-0009)
This publication has 23 references indexed in Scilit:
- Interconnect reliability modeling and analysis for multi-branch interconnect trees2015
- Blech Effect in Interconnects2015
- Physics-based Electromigration Assessment for Power Grid Networks2014
- Beyond Black’s equation: Full-chip EM/SM assessment in 3D IC stackMicroelectronic Engineering, 2014
- Transient modeling of TSV-wire electromigration and lifetime analysis of power distribution network for 3D ICs2013
- Electromigration-induced extrusion failures in Cu/low-k interconnectsJournal of Applied Physics, 2008
- Power grid analysis benchmarks2008
- A physically based model of electromigration and stress-induced void formation in microelectronic interconnectsJournal of Applied Physics, 1999
- Stress evolution due to electromigration in confined metal linesJournal of Applied Physics, 1993
- Electromigration in thin aluminum films on titanium nitrideJournal of Applied Physics, 1976