Dynamic contrast-enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden-angle radial sampling: Preliminary experience
Open Access
- 16 May 2014
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (5) , 1365-1373
Abstract
Purpose To demonstrate dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate with both high spatial and temporal resolution via a combination of golden-angle radial k-space sampling, compressed sensing, and parallel-imaging reconstruction (GRASP), and to compare image quality and lesion depiction between GRASP and conventional DCE in prostate cancer patients. Materials and Methods Twenty prostate cancer patients underwent two 3T prostate MRI examinations on separate dates, one using standard DCE (spatial resolution 3.0 × 1.9 × 1.9 mm, temporal resolution 5.5 sec) and the other using GRASP (spatial resolution 3.0 × 1.1 × 1.1 mm, temporal resolution 2.3 sec). Two radiologists assessed measures of image quality and dominant lesion size. The experienced reader recorded differences in contrast arrival times between the dominant lesion and benign prostate. Results Compared with standard DCE, GRASP demonstrated significantly better clarity of the capsule, peripheral/transition zone boundary, urethra, and periprostatic vessels; image sharpness; and lesion conspicuity for both readers (P < 0.001–0.020). GRASP showed improved interreader correlation for lesion size (GRASP: r = 0.691–0.824, standard: r = 0.495–0.542). In 8/20 cases, only GRASP showed earlier contrast arrival in tumor than benign; in no case did only standard DCE show earlier contrast arrival in tumor. Conclusion High spatiotemporal resolution prostate DCE is possible with GRASP, which has the potential to improve image quality and lesion depiction as compared with standard DCE. J. Magn. Reson. Imaging 2015;41:1365–1373.Keywords
This publication has 45 references indexed in Scilit:
- 3 Tesla multiparametric MRI for GTV-definition of Dominant Intraprostatic Lesions in patients with Prostate Cancer – an interobserver variability studyRadiation Oncology, 2013
- Diagnosis of relevant prostate cancer using supplementary cores from magnetic resonance imaging-prompted areas following multiple failed biopsiesMagnetic Resonance Imaging, 2013
- Influence of imaging and histological factors on prostate cancer detection and localisation on multiparametric MRI: a prospective studyEuropean Radiology, 2013
- Peripheral Zone Prostate Cancer Localization by Multiparametric Magnetic Resonance at 3 TInvestigative Radiology, 2012
- Prostatic cancer surveillance following whole-gland high-intensity focused ultrasound: comparison of MRI and prostate-specific antigen for detection of residual or recurrent diseaseBritish Journal of Radiology, 2012
- Evaluation of semi-quantitative dynamic contrast-enhanced MRI parameters for prostate cancer in correlation to whole-mount histopathologyEuropean Journal of Radiology, 2012
- ESUR prostate MR guidelines 2012European Radiology, 2012
- Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary ObservationsAmerican Journal of Roentgenology, 2011
- Assessment of the effect of haematocrit‐dependent arterial input functions on the accuracy of pharmacokinetic parameters in dynamic contrast‐enhanced MRINMR in Biomedicine, 2011
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010