Abstract
Background: Limited data exist on indicators of durable pulmonary vein isolation (PVI) undergoing cryoballoon ablation (CBA) for atrial fibrillation (AF). We investigated whether balloon temperature and time to PVI can be used to predict early PV reconduction (EPVR), including residual PV conduction and adenosine triphosphate‐induced dormant conduction and the relation between touch‐up ablation of EPVR sites and mid‐term recurrence of AF.Methods: We obtained procedural and outcome data from the records of 130 consecutive patients who underwent CBA and followed up for 13.4 months.Results: EPVR was identified in 86 (17%) PVs of 61 (47%) patients. Balloon temperatures during 30 seconds (−27 ± 5.7°C vs −31 ± 5.5°C), 60 seconds (−36 ± 5.6°C vs −41 ± 5.4°C), and at the nadir point (−41 ± 7.4°C vs −49 ± 7.0°C) were significantly higher, and the time to PVI was longer (90 ± 50 seconds vs 52 ± 29 seconds) in PVs with EPVR than in those without (P < 0.0001 for all). Among PVs without EPVR, the time to PVI was longer and balloon temperature was lower for the left superior pulmonary vein/ right inferior pulmonary vein (LSPV/RIPV) than for the right superior pulmonary vein/left inferior pulmonary vein (RSPV/LIPV) (time: 60 ± 25/73 ± 37 seconds vs 41 ± 31/45 ± 20 seconds, P < 0.0001) (temp: −39.2 ± 11.3/−39.4 ± 8.3°C vs −33.8 ± 10.6/−33.6 ± 6.8°C, P = 0.0023). AF recurrence rates were equivalent between patients with and without EPVR (13% [8/69] vs 15% [9/61], P = 0.845).Conclusions: Cryoballoon temperature and time to PVI appear to be useful in predicting durable PVI, that is, prevention of EPVR, but the balloon temperature and time required for PVI differ between PVs. Although EPVR does not predict AF recurrence, high success rates can be expected when touch‐up ablation of EPVR sites is performed.Keywords
This publication has 30 references indexed in Scilit:
- Mechanistic Insights Into Durable Pulmonary Vein Isolation Achieved by Second-Generation Cryoballoon AblationJournal of Atrial Fibrillation, 2017
- Pulmonary Vein Isolation Versus DefragmentationJACC, 2015
- Adenosine Triphosphate Test After Cryothermal Pulmonary Vein Isolation: Creating Contiguous Lesions Is Essential for Eliminating Dormant ConductionJournal of Cardiovascular Electrophysiology, 2015
- Adenosine-guided pulmonary vein isolation for the treatment of paroxysmal atrial fibrillation: an international, multicentre, randomised superiority trialThe Lancet, 2015
- Adenosine testing after second-generation cryoballoon ablation (ATSCA) study improves clinical success rate for atrial fibrillationEP Europace, 2015
- Mechanisms of Pulmonary Vein Reconnection After Radiofrequency Ablation of Atrial Fibrillation: The Deterministic Role of Contact Force and Interlesion DistanceJournal of Cardiovascular Electrophysiology, 2014
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJACC, 2013
- Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation CryoballoonJournal of Cardiovascular Electrophysiology, 2012
- Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablationHeart, 2010
- Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter AblationCirculation, 2003