Algorithm combination strategy to obtain the second‐order advantage: simultaneous determination of target analytes in plasma using three‐dimensional fluorescence spectroscopy
- 11 April 2012
- journal article
- research article
- Published by Wiley in Journal of Chemometrics
- Vol. 26 (5) , 197-208
Abstract
Although a number of algorithms have established to obtain the well‐known second‐order advantage that quantifies analytes of interest in the presence of interferents, each has associated problems. In this work, for the first time, the optimization procedure of trilinear decomposition has been divided into three subparts, and a novel strategy is developed for assembling the advantages of the alternating trilinear decomposition (ATLD) algorithm, the self‐weighted alternating trilinear decomposition (SWATLD) algorithm, and the parallel factor analysis (PARAFAC) algorithm. The performance of the proposed strategy was evaluated using a simulated data set, a published fluorescence data set together with a new fluorescence data set that simultaneously quantifies procaine and tetracaine in plasma. Results show that the novel method can accurately and effectively estimate the qualitative and quantitative information of analytes of interest. Besides, the resolved profiles are very stable with respect to the number of components as long as the employed number is chosen to be equal or larger than the underlying one. Additionally, the study confirms that better prediction can be obtained by the new strategy when compared with ATLD, SWATLD, and PARAFAC as well as the strategy that employs direct trilinear decomposition method as initial values for PARAFAC. Moreover, the strategy can be directly extended to third‐order or higher‐order data analysis. Copyright © 2012 John Wiley & Sons, Ltd.Keywords
This publication has 32 references indexed in Scilit:
- Mathematical chromatography solves the cocktail party effect in mixtures using 2D spectra and PARAFACTrAC Trends in Analytical Chemistry, 2010
- Multi-way chemometric methodologies and applications: A central summary of our research workAnalytica Chimica Acta, 2009
- T1-Diffusion-Ordered Spectroscopy: Nuclear Magnetic Resonance Mixture Analysis Using Parallel Factor AnalysisAnalytical Chemistry, 2009
- Analytical applications of second-order calibration methodsAnalytica Chimica Acta, 2008
- Analytical Advantages of Multivariate Data Processing. One, Two, Three, Infinity?Analytical Chemistry, 2008
- The application to wastewaters of chemometric approaches to handling problems of highly complex matricesTrAC Trends in Analytical Chemistry, 2007
- A novel efficient way to estimate the chemical rank of high-way data arraysAnalytica Chimica Acta, 2007
- Efficient way to estimate the optimum number of factors for trilinear decompositionAnalytica Chimica Acta, 2001
- On the self‐weighted alternating trilinear decomposition algorithm—the property of being insensitive to excess factors used in calculationJournal of Chemometrics, 2001
- Multicomponent Determination of Chlorinated Hydrocarbons Using a Reaction-Based Chemical Sensor. 3. Medium-Rank Second-Order Calibration with Restricted Tucker ModelsAnalytical Chemistry, 1994