Electric Field and Ion Current Environment of HVdc Transmission Lines: Comparison of Calculations and Measurements
Author:
Top Cited Papers
- 1 January 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 27 (1) , 401-410
Abstract
The electric field and ion current environment under HVdc transmission lines is an important design consideration. The flux tracing method (FTM) for calculating the ground-level electric field and ion current density distributions is reviewed and the possible errors caused by the use of Deutsch's assumption in the FTM are estimated. Experimental data obtained under one dc test line and three operating dc transmission lines are compared with calculations made with the FTM. The results show that the most important factor influencing the electric field and ion current distributions is the corona onset gradient of the conductors, or indirectly, the conductor surface roughness factor. The results also show that for practical dc transmission-line configurations, any errors caused by Deutsch's assumption are quite small compared with the observed variations in experimental data.Keywords
This publication has 12 references indexed in Scilit:
- Electrical environment of the uprated Pacific NW/SW HVDC IntertieIEEE Transactions on Power Delivery, 1989
- Accurate calculation of ion flow field under HVDC bipolar transmission linesIEEE Transactions on Power Delivery, 1988
- A Very Stable Calculation Method for Ion Flow Field of HVDC Transmission LinesIEEE Transactions on Power Delivery, 1987
- HVDC Field and Ion Effects Research at Project UHV: Results of Electric Field and Ion Current MeasurementsIEEE Transactions on Power Apparatus and Systems, 1982
- Calculation of ION Flow Fields of HVDC Transmission Lines By the Finite Element MethodIEEE Transactions on Power Apparatus and Systems, 1981
- The Corona and Radio Interference Performance of the Nelson River HVDC Transmission LinesIEEE Transactions on Power Apparatus and Systems, 1979
- Analysis of Corona Losses on DC Transmission Lines Part II - Bipolar LinesIEEE Transactions on Power Apparatus and Systems, 1969
- Progress Report on the HVDC Test Line of the 400 kV-Forschungsgemeinschaft: Corona Losses and Radio InterferenceIEEE Transactions on Power Apparatus and Systems, 1969
- Analysis of Corona Losses on DC Transmission Lines: I - Unipolar LinesIEEE Transactions on Power Apparatus and Systems, 1969
- XI. The potentials required to maintain currents between coaxial cylindersJournal of Computers in Education, 1914