Relationship between Noise, Dose, and Pitch in Cardiac Multi–Detector Row CT
Authors:
- Andrew N. PrimakAPAndrew N. Primak
- Cynthia H. McColloughCMCynthia H. McCollough
- Michael R. BruesewitzMBMichael R. Bruesewitz
- Jie ZhangJZJie Zhang
- Joel G. FletcherJFJoel G. Fletcher
- 1 November 2006
- journal article
- review article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 26 (6) , 1785-1794
Abstract
In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi–detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi–detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi–detector row CT, dose is increased without a commensurate decrease in noise. Thu...Keywords
This publication has 22 references indexed in Scilit:
- Multi–Detector Row CT Systems and Image-Reconstruction TechniquesRadiology, 2005
- Effect of multislice scanners on patient dose from routine CT examinations in East AngliaBritish Journal of Radiology, 2004
- National Conference on Dose Reduction in CT, with an Emphasis on Pediatric PatientsAmerican Journal of Roentgenology, 2003
- Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide surveyEuropean Radiology, 2003
- Radiation Dose in Computed Tomography of the HeartCirculation, 2003
- Patient Dose in Cardiac Computed TomographyHerz, 2003
- AAPM/RSNA Physics Tutorial for Residents: Topics in CTRadioGraphics, 2002
- FDA Public Health Notification: Reducing Radiation Risk from Computed Tomography for Pediatric and Small Adul PatientsPediatric Radiology, 2002
- Radiation Exposure in Spiral Computed TomographyInvestigative Radiology, 1999
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990