Low-Order Wideband Isolation Transformer Modeling Based on Independent Branch Fitting
- 4 February 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 64 (3) , 874-883
Abstract
This article discusses the wideband modeling of an isolation transformer aiming at studying the transference of differential-mode voltage surges from the primary side to the secondary side. A modeling approach based on the independent fitting of the branch admittances associated with the equivalent pi-circuit of the transformer is proposed and validated. The resulting model is described either as a Norton-type equivalent circuit for time-domain simulations or as an equivalent circuit. The proposed modeling approach is used to calculate differential voltages transferred to the secondary side of the transformer for the application of impulse voltages at the primary side for different load conditions. The model performance is shown to be comparable to that of a pair of models based on the fitting of all elements of the admittance matrix of the transformer with a single set of poles, with the advantage of requiring a reduced number of circuit elements. It is shown that the tested transformer has a resonant behavior that amplifies differential-mode voltage surges with frequency content around 205 kHz. Also, the time-domain response of the transformer presents a damped oscillatory behavior in the no-load condition and a damped behavior if resistive loads are added at the secondary side.Keywords
Funding Information
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (306006/2019-7)
- State of Minas Gerais Research Foundation (TEC-PPM-00280-17)
This publication has 21 references indexed in Scilit:
- Experimental study and circuit analysis model of lightning isolation transformer for railway signal system2016
- IEEE Standard for the Surge Parameters of Isolating Transformers Used in Networking Devices and Equipment2016
- Voltage Transfer Characteristics of an Insulation Transformer Up to 1 MHzIEEE Transactions on Electromagnetic Compatibility, 2016
- Modeling isolation transformer capacitive components in a dual active bridge power conditioner2013
- Wide Band Modeling of Power TransformersIEEE Transactions on Power Delivery, 2004
- Single-phase insulator transformersIEEE Potentials, 2003
- Common mode voltage to differential mode voltage conversion characteristics of shielded transformer in VHF band2003
- Computer code for rational approximation of frequency dependent admittance matricesIEEE Transactions on Power Delivery, 2002
- Characteristics of a special-isolation transformer capable of protecting from high-voltage surges and its performanceIEEE Transactions on Electromagnetic Compatibility, 2001
- Rational approximation of frequency domain responses by vector fittingIEEE Transactions on Power Delivery, 1999