First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system
Open Access
- 10 December 2013
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (1) , 43-60
Abstract
During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm when at least 5 Gy are delivered.Keywords
This publication has 52 references indexed in Scilit:
- A Dose Determination Procedure by PET Monitoring in Proton Therapy: Monte Carlo ValidationIEEE Transactions on Nuclear Science, 2013
- Extension and validation of an analytical model forin vivoPET verification of proton therapy—a phantom and clinical studyPhysics in Medicine & Biology, 2011
- A Time Efficient Optical Model for GATE Simulation of a LYSO Scintillation Matrix Used in PET ApplicationsIEEE Transactions on Nuclear Science, 2010
- Experimental validation of the filtering approach for dose monitoring in proton therapy at low energyPhysica Medica, 2008
- Preliminary results of an in-beam PET prototype for proton therapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Performance of a four-output front-end electronics for multi-anode PMTS readout of scintillator arraysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- On the detector arrangement for in-beam PET for hadron therapy monitoringPhysics in Medicine & Biology, 2006
- Suppression of random coincidences during in-beam PET measurements at ion beam radiotherapy facilitiesIEEE Transactions on Nuclear Science, 2005
- A 62-MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFNIEEE Transactions on Nuclear Science, 2004
- Visualization and Transport of Positron Emission from Proton Activation in vivoScience, 1978