Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies
Authors:
- 2 February 2007
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 16 (7) , 1047-1054
Abstract
A lot of new implant devices for spine surgery are coming onto the market, in which vertebral screws play a fundamental role. The new screws developed for surgery of spine deformities have to be compared to established systems. A biomechanical in vitro study was designed to assess the bone–screw interface fixation strength of seven different screws used for correction of scoliosis in spine surgery. The objectives of the current study were twofold: (1) to evaluate the initial strength at the bone–screw interface of newly developed vertebral screws (Universal Spine System II) compared to established systems (product comparison) and (2) to evaluate the influence of screw design, screw diameter, screw length and bone mineral density on pullout strength. Fifty-six calf vertebral bodies were instrumented with seven different screws (USS II anterior 8.0 mm, USS II posterior 6.2 mm, KASS 6.25 mm, USS II anterior 6.2 mm, USS II posterior 5.2 mm, USS 6.0 mm, USS 5.0 mm). Bone mineral density (BMD) was determined by quantitative computed tomography (QCT). Failure in axial pullout was tested using a displacement-controlled universal test machine. USS II anterior 8.0 mm showed higher pullout strength than all other screws. The difference constituted a tendency (P = 0.108) when compared to USS II posterior 6.2 mm (+19%) and was significant in comparison to the other screws (+30 to +55%, P < 0.002). USS II posterior 6.2 mm showed significantly higher pullout strength than USS 5.0 mm (+30%, P = 0.014). The other screws did not differ significantly in pullout strength. Pullout strength correlated significantly with BMD (P = 0.0015) and vertebral body width/screw length (P < 0.001). The newly developed screws for spine surgery (USS II) show higher pullout strength when compared to established systems. Screw design had no significant influence on pullout force in vertebral body screws, but outer diameter of the screw, screw length and BMD are good predictors of pullout resistance.Keywords
This publication has 64 references indexed in Scilit:
- Anterior Vertebral Body Screw Pullout Testing With The Hollow Modular Anchorage System - A Comparative in vitro Study. Hohltonnenschrauben als neues Verankerungskonzept an der Wirbelsäule - Lastauszugsversuche als biomechanische VergleichsstudieBiomedical Engineering / Biomedizinische Technik, 2003
- Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical platingEuropean Spine Journal, 2002
- Anterior fixation in the osteoporotic spine: cut-out and pullout characteristics of implantsEuropean Spine Journal, 2002
- Biomechanical Evaluation of Anterior and Posterior Fixations in an Unstable Calf Spine ModelSpine, 1997
- Anterior Correction of Idiopathic Scoliosis Using TSRH InstrumentationSpine, 1993
- Physical and mechanical properties of calf lumbosacral trabecular boneJournal of Biomechanics, 1991
- Verankerungsversuche an menschlichen Leichenwirbelkörpern mit Hilfe von verschiedenen SchraubentypenZeitschrift für Orthopädie und ihre Grenzgebiete, 1983
- A Review of the Factors Affecting the Design, Specification and Material Selection of Screws for Use in Orthopaedic SurgeryEngineering in Medicine, 1978
- Force measurements in screw fixationJournal of Biomechanics, 1976
- The Holding Power of Orthopedic Screws In VivoClinical Orthopaedics and Related Research, 1975