Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies
- 28 August 2009
- journal article
- research article
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 105 (1) , 184-194
Abstract
Early detection of kinetic, metabolic, and toxicity (ADME‐Tox) profiles for new drug candidates is of crucial importance during drug development. This article describes a novel in vitro system for the incubation of precision‐cut liver slices (PCLS) under flow conditions, based on a poly(dimethylsiloxane) (PDMS) device containing 25‐µL microchambers for integration of the slices. The microdevice is coupled to a perifusion system, which enables a constant delivery of nutrients and oxygen and a continuous removal of waste products. Both a highly controlled incubation environment and high metabolite detection sensitivity could be achieved using microfluidics. Liver slices were viable for at least 24 h in the microdevice. The compound, 7‐ethoxycoumarin (7‐EC), was chosen to test metabolism, since its metabolism includes both phase I and phase II metabolism and when tested in the conventional well plate system, correlates well with the in vivo situation (De Kanter et al. 2004. Xenobiotica 34(3): 229–241.). The metabolic rate of 7‐EC was found to be 214 ± 5 pmol/min/mg protein in the microdevice, comparable to well plates, and was constant over time for at least 3 h. This perifusion system better mimics the in vivo situation, and has the potential to significantly contribute to drug metabolism and toxicology studies of novel chemical entities. Biotechnol. Bioeng. 2010;105: 184–194.Keywords
This publication has 34 references indexed in Scilit:
- Development of a microfluidic device for the maintenance and interrogation of viable tissue biopsiesLab on a Chip, 2008
- Development of a Microscale Cell Culture Analog To Probe Naphthalene ToxicityBiotechnology Progress, 2008
- Cell Culture Models in Microfluidic SystemsAnnual Review of Analytical Chemistry, 2008
- In situ micropatterning technique by cell crushing for co-cultures inside microfluidic biochipsBiomedical Microdevices, 2007
- Leakage-Free Bonding of Porous Membranes into Layered Microfluidic Array SystemsAnalytical Chemistry, 2007
- Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian HepatocytesAnalytical Chemistry, 2006
- EMPIRICAL VALIDATION OF A RAT IN VITRO ORGAN SLICE MODEL AS A TOOL FOR IN VIVO CLEARANCE PREDICTIONDrug Metabolism and Disposition, 2006
- Can the pharmaceutical industry reduce attrition rates?Nature Reviews Drug Discovery, 2004
- Endogenous nitric oxide is responsible for the early loss of P450 in cultured rat hepatocytesFEBS Letters, 1998
- Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)Analytical Chemistry, 1998