Foreign body reaction to a bioabsorbable interference screw after anterior cruciate ligament reconstruction
Authors:
- 27 February 2009
- journal article
- Published by BMJ in BMJ Case Reports
- Vol. 2009
Abstract
Bioabsorbable interference screws have been effective for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of these screws is low but some unique problems have been reported in the literature. We present a case of unusual tissue reaction to a bioabsorbable interference screw following ACL reconstruction.A young male underwent ACL reconstruction, during which a bioabsorbable interference screw was used for graft fixation at the tibial end. The patient presented with a pretibial swelling at 30 months after the operation. Exploration revealed chalky white remnants of the bioabsorbable screw with no evidence of infection. Histological studies confirmed a foreign body reaction against screw remnants with the presence of multinucleated giant cells.The patient had a full recovery with no compromise to graft stability. Bioabsorbable interference screws are usually inert but can initiate a tissue reaction. The presentation can be as late as 2–3 years postoperatively and may mimic an infection. Satisfactory results can be achieved by proper exploration and debridement.Keywords
This publication has 11 references indexed in Scilit:
- Sterile Pretibial Abscess After Anterior Cruciate Reconstruction From Bioabsorbable Interference Screws: A Report of 2 CasesArthroscopy, 2006
- A New Bioabsorbable Interference Screw: Preliminary Results of a Prospective, Multicenter, Randomized Clinical TrialArthroscopy, 2000
- Bioabsorbable Interference Screws for Graft Fixation in Anterior Cruciate Ligament ReconstructionArthroscopy, 1999
- Pretibial cyst formation after anterior cruciate ligament surgery with soft tissue autograftsArthroscopy, 1998
- Biodegradable Interference Screw Fixation Exhibits Pull-Out Force and Stiffness Similar to Titanium ScrewsThe American Journal of Sports Medicine, 1998
- Metal and biodegradable interference screws: Comparison of failure strengthArthroscopy, 1996
- Preliminary results of an absorbable interference screwArthroscopy, 1995
- Subcutaneous pretibial cyst formation associated with anterior cruciate ligament allografts: A report of four cases and literature reviewArthroscopy, 1995
- A study on the in vitro degradation of poly(lactic acid)Journal of Biomaterials Science, Polymer Edition, 1994
- A biodegradable intraosseous appliance in the treatment of mandibular fractures.1972