Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula
Open Access
- 13 February 2021
- journal article
- research article
- Published by Hindawi Limited in Journal of Analytical Methods in Chemistry
- Vol. 2021, 1-10
Abstract
A simple, easy-to-implement, and green infrared spectroscopic method was developed and validated for the quantitative determination of sildenafil citrate in tablets of unknown manufacturing formula. Homogenized tablet powder with known mass content (, m/m) of sildenafil citrate was mixed with paracetamol to form standard mixtures with different percentages of sildenafil citrate on the total quantity of sildenafil citrate and paracetamol (designated as R). Unknown tablet samples were finely ground and mixed with paracetamol to form test mixtures having R values about 50. Infrared spectra of standard mixtures, measured in attenuated total reflectance mode, in the wavenumber zone from 1800cm−1 to 1300cm−1 were selected and processed by partial least square regression to form the calibration model for quantitation of sildenafil citrate in unknown samples. Spectral responses of test mixtures and the calibration model were used to determine the exact mass content (, m/m) of sildenafil citrate in the powder of unknown tablet samples. The method was fully validated in terms of linearity, precision, and accuracy according to the requirements of current guidelines and was proved as reliable and suitable for the intended application.Keywords
This publication has 8 references indexed in Scilit:
- Quantitative analysis of anti-inflammatory drugs using FTIR-ATR spectrometrySpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2017
- Handbook of Spectroscopy2014
- Quantitative Analysis of Lorazepam in Pharmaceutical Formulation Through FTIR SpectroscopyJournal of Chemistry, 2011
- Simultaneous determination of sulphamethoxazole and trimethoprim in powder mixtures by attenuated total reflection-Fourier transform infrared and multivariate calibrationJournal of Pharmaceutical and Biomedical Analysis, 2009
- Quantitative determination of naltrexone by attenuated total reflectance – FTIR spectrometry using partial least squares (PLS) wavelength selectionJournal of Spectroscopy, 2009
- A practical guide to analytical method validation, including measurement uncertainty and accuracy profilesTrAC Trends in Analytical Chemistry, 2007
- Simultaneous Determination of Levodopa and Carbidopa in Levodopa-Carbidopa Tablets by ATR-FTIR SpectrometryPharmaceutical Development and Technology, 2007
- Investigation of drug release from suspension using FTIR-ATR technique: part I. Determination of effective diffusion coefficient of drugsInternational Journal of Pharmaceutics, 2000