Lesions of the Reflection Pulley of the Long Biceps Tendon
Authors:
- Marco ZanettiMZMarco Zanetti
- Alex TannerATAlex Tanner
- Christian GerberCGChristian Gerber
- Juerg HodlerJHJuerg Hodler
- 1 July 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 34 (7) , 463-9
Abstract
The purpose of this study was to assess the diagnostic value of MR arthrography in detecting a lesion of the common insertion of the coracohumeral and the superior glenohumeral ligaments and the superior border of the subscapularis tendon (pulley lesion), which predisposes to biceps tendon subluxation and subsequent degeneration. Parasagittal T1-weighted turbo spin-echo and axial gradient-echo (three-dimensional fast imaging with steady state-precession [FISP]) MR arthrographic images were obtained in 14 patients with surgically confirmed pulley lesions and in 10 patients with an intact pulley. Various MR arthrographic signs potentially associated with a pulley lesion were evaluated separately and independently in a blinded fashion by two radiologists. Abnormalities of the superior border of the subscapularis tendon on axial and parasagittal images, extra-articular contrast collection, and biceps tendon subluxation were the MR findings of a pulley lesion. The coracohumeral and superior glenohumeral ligaments were not readily visible in all patients and were not helpful in diagnosing pulley lesions in this study. The overall sensitivity for detecting a pulley lesion by MR arthrography was 86% and 93% for readers 1 and 2, with a specificity of 100% and 80% and an accuracy of 92% and 87% (kappa = 0.75). Based on the authors' experience, MR arthrography is valuable in detecting lesions of the reflection pulley of the long biceps tendon, although differentiation from an isolated lesion of the superior border of the subscapularis tendon may not be possible.Keywords
This publication has 13 references indexed in Scilit:
- MR arthrography of the shoulder: normal intraarticular structures and common abnormalities.American Journal of Roentgenology, 1995
- Tears of the supraspinatus tendon associated with “hidden” lesions of the rotator intervalJournal of Shoulder and Elbow Surgery, 1994
- Tears of the anterior portion of the rotator cuff (the subscapularis tendon): MR imaging findings.American Journal of Roentgenology, 1994
- Case report 815Skeletal Radiology, 1993
- Evaluation and Treatment of Biceps Tendon PathologyOrthopedic Clinics of North America, 1993
- Long bicipital tendon of the shoulder: normal anatomy and pathologic findings on MR imaging.American Journal of Roentgenology, 1992
- Medial dislocation of the biceps brachii tendon: appearance at MR imaging.Radiology, 1991
- Capsular ligaments of the shoulderThe American Journal of Sports Medicine, 1990
- Spontaneous Medial Dislocation of the Tendon of the Long Biceps BrachiiClinical Orthopaedics and Related Research, 1986
- Medial Dislocation of the Tendon of the Long Head of the Biceps BrachiiActa Orthopaedica, 1979