Flow Resonance-Induced Temperature Rise for Thermal Impact Enhancement of Cavitation Reactor Systems
Open Access
- 6 June 2026
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 16 (12) , 5729
Abstract
It has been observed in prior research that high thermal impact—resulting from a large temperature difference between hot water vapor and cold liquid water—can enhance the thermal performance of cavitation-induced low-energy nuclear reactions (LENRs) in water, with an estimated increase in the coefficient of performance (COP) of approximately 50% for every 100 °C temperature rise. The temperature of the hot water vapor is primarily determined by the boiler output, which typically represents the highest temperature source and plays a dominant role in reactor performance. In this study, a flow oscillator was designed as an thermal conditioning component for these potential LENR reactor systems using linear flow network analysis (LFNA) to generate flow resonance that elevates the hot vapor temperature, thereby increasing thermal impact and improving LENR performance. LFNA is based on the linearization of the fluid flow equations governing mass and momentum transport and utilizes a fluid-electric circuit analogy. For a fluid flow system, various components can be modeled using analogs of electrical resistance, capacitance, and inductance (R, C, and L), allowing the system behavior to be analyzed similarly to an RLC circuit. Through this analogy, flow resonance phenomena can be predicted, potentially enabling the generation of high-temperature and high-pressure responses that are beneficial to LENR processes. The analytical model was experimentally validated and subsequently applied in the LENR reactor design. The analytical result shows that an output temperature difference exceeding 350 °C can be achieved using a 0.5 m pulse tube at a 46 Hz triggering frequency with 20 kPa perturbation, which indicates a potential COP enhancement of 175% based on prior studies. The result provides a potential mechanism to significantly enhance the thermal impact conditions and promote LENR performance in water-based reactor systems.Keywords
Funding Information
- ATD, Inc.
- National Taiwan Normal University
This publication has 21 references indexed in Scilit:
- A correlation between cavitation bubble temperature, sonoluminescence and interfacial chemistry – A minireviewUltrasonics Sonochemistry, 2022
- Slug frequency for a gas-liquid plug flow: Review and development of a new correlationInternational Communications in Heat and Mass Transfer, 2020
- Study of Venturi tube geometry on the hydrodynamic cavitation for the generation of microbubblesMinerals Engineering, 2019
- A parametric review of sonochemistry: Control and augmentation of sonochemical activity in aqueous solutionsUltrasonics Sonochemistry, 2017
- Extreme conditions during multibubble cavitation: Sonoluminescence as a spectroscopic probeUltrasonics Sonochemistry, 2011
- Influence of resonance tube length on performance of thermoacoustically driven pulse tube refrigeratorCryogenics, 2005
- Fundamentals of Cavitation2005
- Fundamental aspects of sonochemistryUltrasonics, 1992
- Steam bubbling regimes and direct contact condensation heat transfer in highly subcooled waterChemical Engineering Science, 1990
- Electrochemically induced nuclear fusion of deuteriumJournal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1989