Enhanced and Robust Contrast in CEST MRI: Saturation Pulse Shape Design via Optimal Control
Preprint
Abstract
Purpose: To employ optimal control for the numerical design of CEST saturation pulses to maximize contrast and stability against $B_0$ inhomogeneities. Theory and Methods: We applied an optimal control framework for the design pulse shapes for CEST saturation pulse trains. The cost functional minimized both the pulse energy and the discrepancy between the corresponding CEST spectrum and the target spectrum based on a continuous RF pulse. The optimization is subject to hardware limitations. In measurements on a 7 T preclinical scanner, the optimal control pulses were compared to continuous-wave and Gaussian saturation methods. We conducted a comparison of the optimal control pulses were compared to with Gaussian, block pulse trains, and adiabatic spin-lock pulses. Results: The optimal control pulse train demonstrated saturation levels comparable to continuous-wave saturation and surpassed Gaussian saturation by up to 50 \% in phantom measurements. In phantom measurements at 3 T the optimized pulses not only showcased the highest CEST contrast, but also the highest stability against field inhomogeneities. In contrast, block pulse saturation resulted in severe artifacts. Dynamic Bloch-McConnell simulations were employed to identify the source of these artifacts, and underscore the $B_0$ robustness of the optimized pulses. Conclusion: In this work, it was shown that a substantial improvement in pulsed saturation CEST imaging can be achieved by using Optimal Control design principles. It is possible to overcome the sensitivity of saturation to B0 inhomogeneities while achieving CEST contrast close to continuous wave saturation.
Keywords
All Related Versions
This publication has 42 references indexed in Scilit:
- Clinical applications of chemical exchange saturation transfer (CEST) MRIJournal of Magnetic Resonance Imaging, 2017
- Optimizing pulsed‐chemical exchange saturation transfer imaging sequencesMagnetic Resonance in Medicine, 2011
- Optimization of pulse train presaturation for CEST imaging in clinical scannersMagnetic Resonance in Medicine, 2011
- Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protonsMagnetic Resonance in Medicine, 2010
- B1 mapping by Bloch‐Siegert shiftMagnetic Resonance in Medicine, 2010
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- Pulsed magnetization transfer imaging with body coil transmission at 3 Tesla: Feasibility and applicationMagnetic Resonance in Medicine, 2006
- Quantitative description of proton exchange processes between water and endogenous and exogenous agents for WEX, CEST, and APT experimentsMagnetic Resonance in Medicine, 2004
- NMR relaxation times in the human brain at 3.0 teslaJournal of Magnetic Resonance Imaging, 1999
- Pulsed magnetization transfer versus continuous wave irradiation for tissue contrast enhancementJournal of Magnetic Resonance Imaging, 1993