Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair
Open Access
- 14 December 2022
- journal article
- case report
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 17 (1) , 1-5
Abstract
Background: Clinically insignificant hemolytic anemia is occasionally a complication of prosthetic valve replacement. However, hemolysis related to kinked grafts is a very rare complication after central repair for acute aortic dissection. Case presentation: A 42-year-old man had undergone replacement of the ascending aorta and a root repair for type A aortic dissection 6 months previously. Laboratory data showed mild hemolysis 5 months later, and he began to complain of fatigue on exertion. The serum hemoglobin level reduced to 8.6 g/dL, and lactate dehydrogenase levels increased to 3071 IU/L with gross change in urine color, indicating hemoglobinuria. We diagnosed mechanical hemolytic anemia caused by a kinked graft and planned a repeat operation. The kinked graft was resected and graft-graft anastomosis was performed. Postoperatively, the clinical course was uneventful, and the hemolytic anemia completely resolved. Conclusion: We herein report a case of hemolytic anemia caused by kinking of the graft 6 months after acute aortic dissection repair. The diagnosis was swiftly made, and the patient was successfully managed with redo surgery.Keywords
All Related Versions
This publication has 14 references indexed in Scilit:
- Long-term size follow-up of knitted Dacron grafts (Gelseal ) used in the ascending aortaInteractive CardioVascular and Thoracic Surgery, 2012
- Severe non-valve-related hemolytic anemia following aortic root replacementInteractive CardioVascular and Thoracic Surgery, 2010
- Vascular Graft Replacement of the Ascending and Descending Aorta: Do Dacron Grafts Grow?The Annals of Thoracic Surgery, 2007
- Aortic Enlargement and Late Reoperation After Repair of Acute Type A Aortic DissectionThe Annals of Thoracic Surgery, 2007
- A surgical case for hemolytic anemia after ascending and total arch replacement.2005
- Hemolysis after mitral valve repair: mechanisms and treatmentThe Annals of Thoracic Surgery, 2004
- A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flowJournal of Biomechanics, 2001
- Gelseal® versus Gelweave® dacron prosthetic grafts in the descending thoracic aorta: a two-year computed tomography scan follow-up studyCardiovascular Surgery, 1999
- Turbulent shear stress measurements in the vicinity of aortic heart valve prosthesesJournal of Biomechanics, 1986
- Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stressesBiorheology, 1984