Biomechanical Consequences of Anterior Column Fracture of the Acetabulum
Authors:
- Andrew J. HamelAHAndrew J. Hamel
- Neil A. SharkeyNSNeil A. Sharkey
- Brian K. BayBBBrian K. Bay
- Steven A. OlsonSOSteven A. Olson
- 1 November 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 12 (8) , 547-552
Abstract
To measure biomechanical consequences of a high anterior column acetabular fracture. A benchtop biomechanical model using quasi-static loading of the hip joint in a simulated single-leg stance. Pressure-sensitive prescale (Fuji) film was used to determine hip joint loading parameters. Six cadaveric hemipelvi with one hip tested in each specimen. Three right and three left hips were tested. Creation of an anterior column fracture with anatomic reduction and fixation, followed by gap malreduction/fixation, and subsequently step malreduction/fixation. Contact pressure, contact area, and load distribution throughout the hip joint in each experimental condition. There were significant increases in load (p<0.01) and peak pressures (p<0.01) in the superior acetabular region after gap malreduction and in peak contact pressures after step malreduction (p<0.01) as compared with the intact acetabulum. Anatomic reduction was not associated with increased mean or peak contact pressures (in any region). Both step and gap malreductions of a high anterior column fracture resulted in significantly increased peak contact pressures in the superior acetabular region. These biomechanical data cannot be directly extrapolated to clinical applications, but these data suggest that anatomic reduction of anterior column fracture affords the best opportunity to restore contact pressures, contact area, and load distribution within the hip to levels similar to those seen in the intact acetabulum.Keywords
This publication has 27 references indexed in Scilit:
- Effect of Impact Load on Articular Cartilage: Development of an Intra-Articular Fracture ModelJournal of Orthopaedic Trauma, 1997
- Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strainsJournal of Biomechanics, 1997
- Hip joint loading during walking and running, measured in two patientsJournal of Biomechanics, 1993
- The effects of contact pressure elevations and aseptic necrosis on the long‐term outcome of congenital hip dislocationJournal of Orthopaedic Research, 1990
- In vitro contact stress distributions in the natural human hipJournal of Biomechanics, 1983
- Stress on the articular surface of the hip joint in healthy adults and persons with idiopathic osteoarthrosis of the hip jointJournal of Biomechanics, 1981
- CONTACT PRESSURES IN THE LOADED HUMAN CADAVER HIPThe Journal of Bone and Joint Surgery. British volume, 1975
- WEIGHT-BEARING AREAS IN THE HUMAN HIP JOINTThe Journal of Bone and Joint Surgery. British volume, 1972
- The transmission of load through the human hip jointJournal of Biomechanics, 1971
- Incongruent Surfaces in the Human Hip JointNature, 1968