Morphological Analysis of the Left Ventricular Endocardial Surface Using a Bag-of-Features Descriptor
Authors:
- 12 September 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 19 (4) , 1483-1493
Abstract
The limitations of conventional imaging techniques have hitherto precluded a thorough and formal investigation of the complex morphology of the left ventricular (LV) endocardial surface and its relation to the severity of coronary artery disease (CAD). However, recent developments in high-resolution multirow-detector computed tomography (MDCT) scanner technology have enabled the imaging of the complex LV endocardial surface morphology in a single heartbeat. Analysis of high-resolution computed tomography images from a 320-MDCT scanner allows for the noninvasive study of the relationship between the percent diameter stenosis (DS) values of the major coronary arteries and localization of the cardiac segments affected by coronary arterial stenosis. In this paper, a novel approach for the analysis of the nonrigid LV endocardial surface from MDCT images, using a combination of rigid body transformation-invariant shape descriptors and a more generalized isometry-invariant Bag-of-Features descriptor, is proposed and implemented. The proposed approach is shown to be successful in identifying, localizing, and quantifying the incidence and extent of CAD and, thus, is seen to have a potentially significant clinical impact. Specifically, the association between the incidence and extent of CAD, determined via the percent DS measurements of the major coronary arteries, and the alterations in the endocardial surface morphology is formally quantified. The results of the proposed approach on 16 normal datasets and 16 abnormal datasets exhibiting CAD with varying levels of severity are presented. A multivariable regression test is employed to test the effectiveness of the proposed morphological analysis approach. Experiments performed on a strictly leave-one-out basis are shown to exhibit a distinct and interesting pattern in terms of the correlation coefficient values within the cardiac segments, where the incidence of coronary arterial stenosis is localized.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Learning Spectral Descriptors for Deformable Shape CorrespondenceIEEE Transactions on Pattern Analysis and Machine Intelligence, 2013
- The wave kernel signature: A quantum mechanical approach to shape analysis2011
- 4D Shape Registration for Dynamic Electrophysiological Cardiac Mapping2006
- Boosting and Nonparametric Based Tracking of Tagged MRI Cardiac Boundaries2006
- Distinctive Image Features from Scale-Invariant KeypointsInternational Journal of Computer Vision, 2004
- Robust Real-Time Myocardial Border Tracking for Echocardiography: An Information Fusion ApproachIEEE Transactions on Medical Imaging, 2004
- Endocardial Boundary E timation and Tracking in Echocardiographic Images using Deformable Template and Markov Random FieldsPattern Analysis and Applications, 2001
- 3D-shape-based retrieval within the MPEG-7 framework2001
- A multiple active contour model for cardiac boundary detection on echocardiographic sequencesIEEE Transactions on Medical Imaging, 1996
- Restoration of the velocity field of the heart from two-dimensional echocardiogramsIEEE Transactions on Medical Imaging, 1989