A glow discharge technique has been developed and applied to the conditioning of the large (38 m3) Poloidal Divertor Experiment (PDX) vacuum vessel. The discharge parameters and working gas (H2) were chosen to maximize C and O removal and minimize metal sputtering. The glow discharge was produced by biasing one or two internal anodes at 400 V to sustain a discharge current of 2–4 A per anode. Purified H2 at a pressure of 3×10−2 Torr was flowed through PDX at ∠10 Torr l/s. The effectiveness of the glow discharge conditioning was monitored by measuring impurity gas (CH4, C2H4, and CO) exhaust rates by mass spectrometry and C and O surface removal rates by in situ AES and XPS. Initial glow discharge operation was accompanied by frequent arcing which subsequently decreased with time. Low Zeff (?2) high-power discharges were obtained in PDX after 120 h of glow discharge treatment, during which more than 100 equivalent monolayers of C and O were removed from the vessel.