Compactly Supported Radial Basis Function-Based Meshless Method for Photon Propagation Model of Fluorescence Molecular Tomography
Authors:
- 18 August 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 36 (2) , 366-373
Abstract
Fluorescence Molecular Tomography (FMT) is a powerful imaging modality for the research of cancer diagnosis, disease treatment and drug discovery. Via three-dimensional (3-D) imaging reconstruction, it can quantitatively and noninvasively obtain the distribution of fluorescent probes in biological tissues. Currently, photon propagation of FMT is conventionally described by the Finite Element Method (FEM), and it can obtain acceptable image quality. However, there are still some inherent inadequacies in FEM, such as time consuming, discretization error and inflexibility in mesh generation, which partly limit its imaging accuracy. To further improve the solving accuracy of photon propagation model (PPM), we propose a novel compactly supported radial basis functions (CSRBFs)-based meshless method (MM) to implement the PPM of FMT. We introduced a series of independent nodes and continuous CSRBFs to interpolate the PPM, which can avoid complicated mesh generation. To analyze the performance of the proposed MM, we carried out numerical heterogeneous mouse simulation to validate the simulated surface fluorescent measurement. Then we performed an in vivo experiment to observe the tomographic reconstruction. The experimental results confirmed that our proposed MM could obtain more similar surface fluorescence measurement with the golden standard (Monte-Carlo method), and more accurate reconstruction result was achieved via MM in in vivo application.Keywords
Funding Information
- National Natural Science Foundation of China (81571836, 81227901, 61231004, 61501462, KKA309004533)
- Open Research Project from SKLMCCS (20150103)
- Beijing Natural Science Foundation (7164270)
- Fundamental Research Funds for the Central Universities (2015JBM026)
- China Postdoctoral Science Foundation (2015M570032)
This publication has 44 references indexed in Scilit:
- Molecular Optical Simulation Environment (MOSE): A Platform for the Simulation of Light Propagation in Turbid MediaPLOS ONE, 2013
- FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography–X-ray computed tomographyNature Methods, 2012
- A Molecular Imaging Primer: Modalities, Imaging Agents, and ApplicationsPhysiological Reviews, 2012
- Fluorescence Molecular Tomography: Principles and Potential for Pharmaceutical ResearchPharmaceutics, 2011
- An Efficient Numerical Method for General $L_{p}$ Regularization in Fluorescence Molecular TomographyIEEE Transactions on Medical Imaging, 2010
- Light transport in biological tissue using three-dimensional frequency-domain simplified spherical harmonics equationsPhysics in Medicine & Biology, 2009
- Meshless methods: A review and computer implementation aspectsMathematics and Computers in Simulation, 2008
- FLUORESCENCE MOLECULAR IMAGINGAnnual Review of Biomedical Engineering, 2006
- Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility studyPhysics in Medicine & Biology, 2005
- Compactly supported positive definite radial functionsAdvances in Computational Mathematics, 1995