Meta-analysis of randomised trials comparing the effectiveness of miniaturised versus conventional cardiopulmonary bypass in adult cardiac surgery
Authors:
Abstract
Objectives: The aim of this meta-analysis is to summarise the results of prospective, randomised studies comparing miniaturised (Mini-CPB) versus conventional cardiopulmonary bypass (C-CPB). Design: Meta-analysis of randomised trials. Methods: After retrieval from literature search of 33 comparative studies, 13 studies have been included in this meta-analysis. Results: There were 562 patients in the Mini-CPB group and 599 in the C-CPB group. Mini-CPB was associated with a somewhat lower mortality during the immediate postoperative period (1.1% vs 2.2%, OR 0.58, 95% CI 0.23 to 1.47, p = 0.25). Postoperative stroke rate was significantly lower in the Mini-CPB group (0.2% vs 2.0%, OR 0.25, 95% CI 0.06 to 1.00, p = 0.05). The length of stay in intensive care unit was similar in the study groups (mean difference: −0.01, 95% CI −0.14 to 0.12, p = 0.87). Mini-CPB was associated with a significantly lower amount of postoperative blood loss (mean difference: −96.55, 95% CI −147.48 to −45.62, p = 0.0002) along with a higher platelet count 6 h after surgery (mean difference: 23 480, 95% CI 2 130 to 44 830, p = 0.03). The risk of resternotomy for bleeding was similar in the study groups (OR 1.06, 95% CI 0.32 to 3.57, p = 0.92). Conclusions: This meta-analysis suggests that the use of Mini-CPB may be associated with lower risk of postoperative stroke and blood losses and with a somewhat decreased mortality. However, due to the large heterogeneity of methods and the small number of studies and patients evaluated so far, larger and homogeneous studies should be performed to obtain more conclusive results on the safety and efficacy of Mini-CPB.Keywords
This publication has 33 references indexed in Scilit:
- Comparison of Mini-Cardiopulmonary Bypass System With Air-Purge Device to Conventional Bypass SystemThe Annals of Thoracic Surgery, 2008
- Minimal Extracorporeal Circulation is a Promising Technique for Coronary Artery Bypass GraftingThe Annals of Thoracic Surgery, 2007
- Minimal cardiopulmonary bypass attenuates neutrophil activation and cytokine release in coronary artery bypass graftingJournal of Artificial Organs, 2007
- Attenuated Renal and Intestinal Injury After Use of a Mini-Cardiopulmonary Bypass SystemThe Annals of Thoracic Surgery, 2007
- Minimally Invasive Closed Circuit Versus Standard Extracorporeal Circulation for Aortic Valve ReplacementThe Annals of Thoracic Surgery, 2007
- Mini–Cardiopulmonary Bypass System: Results of a Prospective Randomized StudyThe Annals of Thoracic Surgery, 2006
- Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypassAmerican Heart Journal, 2006
- Miniaturized Cardiopulmonary Bypass in Coronary Artery Bypass Surgery: Marginal Impact on Inflammation and Coagulation but Loss of Safety MarginsThe Annals of Thoracic Surgery, 2005
- Initial Experience With a Minimized Extracorporeal Bypass System: Is There a Clinical Benefit?The Annals of Thoracic Surgery, 2005
- Comparison of minimally invasive closed circuit extracorporeal circulation with conventional cardiopulmonary bypass and with off-pump technique in CABG patients: selected parameters of coagulation and inflammatory systemEuropean Journal of Cardio-Thoracic Surgery, 2005