An Approach to an Inhibition Electronic Tongue to Detect On-Line Organophosphorus Insecticides Using a Computer Controlled Multi-Commuted Flow System
Open Access
Abstract
An approach to an inhibition bioelectronic tongue is presented. The work is focused on development of an automated flow system to carry out experimental assays, a custom potentiostat to measure the response from an enzymatic biosensor, and an inhibition protocol which allows on-line detections. A Multi-commuted Flow Analysis system (MCFA) was selected and developed to carry out assays with an improved inhibition method to detect the insecticides chlorpyrifos oxon (CPO), chlorfenvinfos (CFV) and azinphos methyl-oxon (AZMO). The system manifold comprised a peristaltic pump, a set of seven electronic valves controlled by a personal computer electronic interface and software based on LabView® to control the sample dilutions into the cell. The inhibition method consists in the injection of the insecticide when the enzyme activity has reached the plateau of the current; with this method the incubation time is avoided. A potentiostat was developed to measure the response from the enzymatic biosensor. Low limits of detection of 10 nM for CPO, CFV, and AZMO were achieved.Keywords
This publication has 27 references indexed in Scilit:
- Biosensors based on cholinesterase inhibition for insecticides, nerve agents and aflatoxin B1 detection (review)Microchimica Acta, 2010
- Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongueBiosensors and Bioelectronics, 2009
- Retro-review of flow-injection analysisTrAC Trends in Analytical Chemistry, 2008
- Electronic Tongue Using an Enzyme Inhibition Biosensor Array for the Resolution of Pesticide MixturesElectroanalysis, 2007
- Highly sensitive detection of organophosphorus insecticides using magnetic microbeads and genetically engineered acetylcholinesteraseBiosensors and Bioelectronics, 2007
- How flow-injection analysis (FIA) over the past 25 years has changed our way of performing chemical analysesTrAC Trends in Analytical Chemistry, 2007
- Enzyme immobilization procedures on screen-printed electrodes used for the detection of anticholinesterase pesticidesAnalytica Chimica Acta, 2004
- Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticidesAnalytica Chimica Acta, 2002
- A potentiostat based on a voltage-controlled current source for use with amperometric gas sensorsIEEE Transactions on Instrumentation and Measurement, 1992
- Sequential injection: a new concept for chemical sensors, process analysis and laboratory assaysAnalytica Chimica Acta, 1990