How accurate is a CT-based dose calculation on a pencil beam TPS for a patient with a metallic prosthesis?
Author:
- 21 August 2001
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (9) , N227-N234
Abstract
The accuracy of a CT-based dose calculation on a treatment planning system (TPS) for a radiotherapy patient with a metallic prosthesis has not previously been reported. In this study, the accuracy of the CT-based inhomogeneity correction on a pencil beam TPS (Helax TMS) was determined in a phantom containing a metallic prosthesis. A steel prosthesis phantom and a titanium prosthesis phantom were investigated. The phantoms were CT-scanned and dose plans produced on the TPS, using the CT images to provide density information for the inhomogeneity corrections. Verification measurements were performed on a linear accelerator for 6 and 15 MV x-rays. Measured dose profiles at three different depths were compared to the calculations of the TPS. For the titanium prosthesis and for 6 MV x-rays, the TPS overestimated the beam attenuation by approximately 20% at 15 and 20 cm depths in the phantom. This is due to a limitation in the density allocation of this TPS: any Hounsfield number (HN) above a certain threshold is allocated the density of steel. For the steel prosthesis, the TPS performed the correct mapping of HN to mass density. The dose calculation was within 6% for 6 MV x-rays at 15 and 20 cm depths. However. the accuracy of dose calculation varied with beam energy and depth, with large errors in the region close to the prosthesis. The TPS overestimated the dose by 11% for 6 MV and 15% for 15 MV x-rays at 11 cm depth. 2.5 cm beyond the steel prosthesis. These results highlight the limitations in the density allocation of this TPS and demonstrate shortcomings in the pencil beam dose calculation.Keywords
This publication has 15 references indexed in Scilit:
- Dose attenuation through a titanium alloy hip prosthesisMedical Dosimetry, 2000
- Traditional and MLC based dose compensator design for patients with hip prostheses undergoing pelvic radiation therapyMedical Dosimetry, 1999
- Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring ReconstructionJournal of Computer Assisted Tomography, 1997
- Prostatic thermoluminescent dosimeter analysis in a patient treated with 18 mv x rays through a prosthetic hipInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- A pencil beam model for photon dose calculationMedical Physics, 1992
- In vivo isocenter dose in two hip prosthesis patientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaMedical Physics, 1989
- Hip prostheses during pelvic irradiation: Effects and correctionsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1988
- Reduction of CT artifacts caused by metallic implants.Radiology, 1987
- Radiotherapy treatment planning for patients fitted with prosthesesBritish Journal of Radiology, 1984