Time‐gated fluorescence lifetime imaging and microvolume spectroscopy using two‐photon excitation
Authors:
- 1 July 1998
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 191 (1) , 39-51
Abstract
A scanning microscope utilizing two‐photon excitation in combination with fluorescence lifetime contrast is presented. The microscope makes use of a tunable femtosecond titanium:sapphire laser enabling the two‐photon excitation of a broad range of fluorescent molecules, including UV probes. Importantly, the penetration depth of the two‐photon exciting (infra)red light is substantially greater than for the corresponding single‐photon wavelength while photobleaching is significantly reduced.The time structure of the Ti:Sa laser can be employed in a straightforward way for the realization of fluorescence lifetime imaging. The fluorescence lifetime is sensitive to the local environment of the fluorescent molecule. This behaviour can be used for example to quantify concentrations of ions, such as pH and Ca2+, or pO2 and pCO2. In the set‐up presented here the fluorescence lifetime imaging is accomplished by time‐gated single photon counting.The performance and optical properties of the microscope are investigated by a number of test measurements on fluorescent test beads. Point‐spread functions calculated from measurements on 230‐nm beads using an iterative restoration procedure compare well with theoretical expectations.Lifetime imaging experiments on a test target containing two different types of test bead in a fluorescent buffer all with different lifetimes (2.15 ns, 2.56 ns and 3.34 ns) show excellent quantitative agreement with reference values obtained from time correlated single photon counting measurements. Moreover, the standard deviation in the results can be wholly ascribed to the photon statistics.Measurements of acridine orange stained biofilms are presented as an example of the potential of two‐photon excitation combined with fluorescence lifetime contrast. Fluorescence lifetime and intensity images were recorded over the whole sample depth of 100 μm. Fluorescence intensity imaging is seriously hampered by the rapid decrease of the fluorescence signal as a function of the depth into the sample. Fluorescence lifetime imaging on the other hand is not affected by the decrease of the fluorescence intensity.Keywords
This publication has 45 references indexed in Scilit:
- Application of fluorescence lifetime imaging microscopy to the investigation of intracellular PDT mechanismsBioimaging, 1997
- Proceedings of fluorescence lifetime imaging meetingScanning, 1996
- Grating compensation of third-order material dispersion in the normal dispersion regime: Sub-100-fs chirped-pulse amplification using a fiber stretcher and grating-pair compressorIEEE Journal of Quantum Electronics, 1995
- Time- and wavelength-resolved spectroscopy in two-photon excited fluorescence microscopyJournal of Microscopy, 1994
- Improvement of lateral resolution in far-field fluorescence light microscopy by using two-photon excitation with offset beamsOptics Communications, 1994
- Fundamental improvement of resolution with a 4Pi-confocal fluorescence microscope using two-photon excitationOptics Communications, 1992
- Imaging of bacterial cells by fluorescence exclusion using scanning confocal laser microscopyJournal of Microbiological Methods, 1992
- Two-Photon Laser Scanning Fluorescence MicroscopyScience, 1990
- Prism-pair dispersive delay lines in optical pulse compressionOptics Letters, 1987
- Resolution of the fluorescence lifetimes in a heterogeneous system by phase and modulation measurementsThe Journal of Physical Chemistry, 1981