Efficacy of high‐intensity focused ultrasonography for noninvasive body sculpting in Chinese patients
- 3 March 2014
- journal article
- clinical trial
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 46 (4) , 263-269
Abstract
Background and Objectives: High‐intensity focused ultrasound (HIFU) is a noninvasive technology for body contouring. HIFU is focused within the subcutaneous adipose tissue, causing coagulative necrosis and cell death. The objective of this study is to evaluate the effectiveness of a HIFU device for sculpting of the abdomen.Materials and Methods: The system has a set focal depth of 1.3 cm. Twelve subjects with adipose thickness no less than 2.5 cm who met the screening criteria were recruited. Each subject received one treatment to the abdomen. The total fluence used per site was 150–165 J/cm2 with a mean of 161 J/cm2. The waist circumference at iliac crest and the point of maximum circumference were recorded at baseline, 4, 8, and 12 weeks post‐treatment, as well as their weight and BMI. Subjects' rating on comfort level and satisfaction were collected via questionnaires at every follow‐up. Standardized photographs were also taken with the Canfield System® at each visit.Results: Seven out of 12 subjects were satisfied with the outcome and 9 out of 12 would recommend this treatment to their friends and family. There was statistically significant improvement in the waist circumference measured at both the iliac crest (P‐value 0.013, 0.002, 0.005) and maximum waistline (P‐value 0.003, 0.034, 0.023) at 4, 8, 12 weeks post‐treatment. Spearman's rho for correlation of energy level versus improvement showed that at 12 weeks post‐treatment follow‐up, the improvement significantly correlated with the total fluence per treatment (P‐value 0.041). The higher the total fluence delivered, the larger the decrease in waist circumference.Conclusions: High‐intensity focused ultrasound effectively decreases waist circumference in Chinese. The higher the total fluence delivered, the larger the decrease in waist circumference was observed. Lasers Surg. Med. 46:263–269, 2014.Keywords
This publication has 12 references indexed in Scilit:
- Toward real-time temperature monitoring in fat and aqueous tissue during magnetic resonance-guided high-intensity focused ultrasound using a three-dimensional proton resonance frequency T1 methodMagnetic Resonance in Medicine, 2013
- Safety and Tolerability of High-Intensity Focused Ultrasonography for Noninvasive Body Sculpting: 24-Week Data From a Randomized, Sham-Controlled StudyAesthetic Surgery Journal, 2012
- Non‐invasive cryolipolysis for body contouring in Chinese—a first commercial experienceLasers in Surgery and Medicine, 2012
- Randomized Sham-Controlled Trial to Evaluate the Safety and Effectiveness of a High-Intensity Focused Ultrasound Device for Noninvasive Body SculptingPlastic and Reconstructive Surgery, 2011
- Evaluation of a Novel High-Intensity Focused Ultrasound Device: Preclinical Studies in a Porcine ModelAesthetic Surgery Journal, 2011
- High-Intensity Focused Ultrasound Effectively Reduces Waist Circumference by Ablating Adipose Tissue from the Abdomen and Flanks: A Retrospective Case SeriesAesthetic Plastic Surgery, 2010
- The use of focused ultrasound for non‐invasive body contouring in AsiansLasers in Surgery and Medicine, 2009
- High-Intensity Focused Ultrasound Effectively Reduces Adipose TissueSeminars in Cutaneous Medicine and Surgery, 2009
- High intensity focused ultrasound lithotripsy with cavitating microbubblesMedical & Biological Engineering & Computing, 2009
- High-intensity focused ultrasound for the targeted destruction of uterine tissues: experiences from a pilot study using a mobile HIFU unitArchives of Gynecology and Obstetrics, 2007