Antimicrobial Efficacy and Permeability of Various Sealing Materials in Two Different Types of Implant–Abutment Connections
Open Access
- 21 July 2022
- journal article
- research article
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (14) , 8031
Abstract
The presence of a microgap along an implant–abutment connection (IAC) is considered the main disadvantage of two-piece implant systems. Its existence may lead to mechanical and biological complications. Different IAC designs have been developed to minimise microleakage through the microgap and to increase the stability of prosthodontic abutments. Furthermore, different sealing materials have appeared on the market to seal the gap at the IAC. The purpose of this study was to evaluate the antimicrobial efficacy and permeability of different materials designed to seal the microgap, and their behaviour in conical and straight types of internal IACs. One hundred dental implants with original prosthodontic abutments were divided into two groups of fifty implants according to the type of IAC. Three different sealing materials (GapSeal, Flow.sil, and Oxysafe gel) were applied in the test subgroups. The contamination of implant–abutment assemblies was performed by a joint suspension containing Candida albicans and Staphylococcus aureus. It was concluded that the IAC type had no significant influence on microleakage regarding microbial infection. No significant difference was found between the various sealing agents. Only one sealing agent (GapSeal) was found to significantly prevent microleakage. A complete hermetic seal was not achieved with any of the sealing agents tested in this study.Keywords
This publication has 32 references indexed in Scilit:
- Pharmacological Properties and Molecular Mechanisms of Thymol: Prospects for Its Therapeutic Potential and Pharmaceutical DevelopmentFrontiers in Pharmacology, 2017
- Microleakage at the Different Implant Abutment Interface: A Systematic ReviewJournal of Clinical and Diagnostic Research, 2017
- Evaluation of resistance against bacterial microleakage of a new conical implant-abutment connection versus conventional connections: an in vitro study.2016
- Peri-Implant Infections of Oral Biofilm Etiology2014
- Efficacy of Antibacterial Sealing Gel and O-Ring to Prevent Microleakage at the Implant Abutment Interface: An In Vitro StudyJournal of Oral Implantology, 2014
- Patient-specific Analysis of Periodontal and Peri-implant MicrobiomesJournal of Dental Research, 2013
- Cluster of Bacteria Associated with Peri‐ImplantitisClinical Implant Dentistry and Related Research, 2013
- Evaluation of Microgap Size and Microbial Leakage in the Connection Area of 4 Abutments With Straumann (ITI) ImplantJournal of Oral Implantology, 2012
- Bacteria and cell cytocompatibility studies on coated medical grade titanium surfacesJournal of Biomedical Materials Research Part A, 2006
- Silicone sealants and structural adhesivesInternational Journal of Adhesion and Adhesives, 2001