In vivo assessment of regenerate axial stiffness in distraction osteogenesis
Authors:
- Harald SteenHSHarald Steen
- 1 March 2005
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 23 (2) , 494-498
Abstract
This paper presents an in vivo test for assessment of regenerate axial stiffness after the distraction phase of lengthening therapy. The test result supplements radiography in evaluating bone healing and assists in determining when the regenerate stiffness is sufficient for removal of the external fixator. The test is non‐invasive and does not require fixator removal. The theoretical basis for the method is that an externally applied load is shared between the fixator and the regenerating bone. The amount of load carried by the regenerate depends on its axial stiffness, which increases with advanced mineralization. By measuring the force in the fixator while applying a known external load to the limb, the load‐share ratio between fixator and limb can be assessed. A load‐share ratio of 100% indicates that the entire load is carried by the fixator. The ratio decreases as the regenerate structure gradually stiffens. In a clinical trial of 22 individuals with tibial lengthening, the fixator was removed when the load‐share ratio dropped below 10%. None of the patients experienced fracture after removal of the fixator. © 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.Keywords
This publication has 34 references indexed in Scilit:
- Fracture Stiffness in Callotasis Determined by Dual-Energy X-Ray Absorptiometry ScanningJournal of Pediatric Orthopaedics B, 2001
- Deformation across the zone of callotasis during loading. Radiostereometric analysis in a patient with achondroplasiaJournal of Orthopaedic Research, 2001
- Quantitative assessment of in vivo bone regeneration consolidation in distraction osteogenesisJournal of Orthopaedic Research, 2000
- Mechanical Performance of External Fixators With Wires for the Treatment of Bone Fractures—Part II: Wire Tension and SlippageJournal of Biomechanical Engineering, 1993
- A role for ultrasound in limb lengtheningBritish Journal of Radiology, 1992
- Radiographic imaging for Ilizarov limb lengthening in childrenPediatric Radiology, 1991
- Quantification of bone healing: Comparison of QCT, SPA, MRI, and DEXA in dog osteotomiesActa Orthopaedica, 1990
- The Tension-Stress Effect on the Genesis and Growth of TissuesClinical Orthopaedics and Related Research, 1989
- Design and performance of a fracture monitoring transducerJournal of Biomedical Engineering, 1988
- EFFECT OF CONTROLLED AXIAL MICROMOVEMENT ON HEALING OF TIBIAL FRACTURESThe Lancet, 1986