Abstract
This research investigates the detection of the detailed static air-gap eccentricity position (SAGE) at both ends of non-salient pole synchronous generators (SG). Differently from the previous studies, the detection method proposed does not necessitate the installation of invasive sensors inside the generator and instead it is based on two groups of symmetrically distributed search coils placed at both end-sides outside the generator. The root mean square (RMS) value comparison in electromotive forces (EMFs) of the search coils is then employed to assess the exact SAGE position of each end-side. Numerical 3D finite element calculation together with an experimental campaign on a two-pole 3000rpm CS-5 prototype synchronous generator validates the effectiveness of the proposed method. It is shown that the maximum assessment error by using four external search coils at each end is 15.1%, while by setting more coils the error can be significantly reduced. Since this proposed method has no need to install invasive search coils inside the generator, it is more convenient for field testing and helps improve the cost-performance of online SAGE condition monitoring.
Funding Information
  • National Natural Science Foundation of China (51777074)
  • Natural Science Foundation of Hebei Province (E2019502047)
  • Chinese Fundamental Research Funds for the Central Universities (2020MS114, 2018YQ03)
  • Third Top Youth Talent Support Program of Hebei Province ([2018]-27)

This publication has 32 references indexed in Scilit: