Vagal stimulation and prevention of sudden death in conscious dogs with a healed myocardial infarction.
- 1 May 1991
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 68 (5) , 1471-1481
Abstract
The interest for the antifibrillatory effect of vagal stimulation has been largely limited by the fact that this concept seemed restricted to acute experiments in anesthetized animals. To explore the potentially protective role of vagal stimulation in conscious animals we developed a chronically implantable device to be placed around the cervical right vagus. An anterior myocardial infarction was produced in 161 dogs; 1 month later an exercise stress test was performed on the 105 survivors. Toward the end of the test the circumflex coronary artery was occluded for 2 minutes. Fifty-nine (56%) dogs developed ventricular fibrillation and, before this test was repeated, were assigned either to a control group (n = 24) or to be instrumented with the vagal device (n = 35). Five dogs were excluded because of electrode malfunction. Compared with the heart rate level attained after 30 seconds of occlusion during exercise in the control test, vagal stimulation led to a decrease of approximately 75 beats/min (from 255 +/- 33 to 170 +/- 36 beats/min, p less than 0.001). In the control group 22 (92%) of 24 dogs developed ventricular fibrillation during the second exercise and ischemia test. By contrast, during vagal stimulation ventricular fibrillation occurred in only 3 (10%) of the 30 dogs tested and recurred in 26 (87%) during an additional exercise and ischemia test in the control condition (p less than 0.001 versus the vagal stimulation test; internal control analysis). Combined analysis of the tests performed in the control condition showed that ventricular fibrillation was reproducible in 48 (89%) of the 54 dogs tested. The protective effect of vagal stimulation was also significant in the group comparison analysis and even after exclusion of those four dogs in which ventricular fibrillation was not reproducible (92% versus 11.5%, control versus vagal stimulation, p less than 0.001). When heart rate was kept constant by atrial pacing, the vagally mediated protection was still significant (p = 0.015) as five (55%) of nine dogs survived the test. This study shows that vagal stimulation, performed shortly after the onset of an acute ischemic episode in conscious animals with a healed myocardial infarction, can effectively prevent ventricular fibrillation. This striking result seems to depend on multiple mechanisms having a synergistic action. The decrease in heart rate is an important but not always essential protective mechanism. The electrophysiological effects secondary to the vagally mediated antagonism of the sympathetic activity on the heart are likely to play a major role.Keywords
This publication has 33 references indexed in Scilit:
- Heart rate variability before and after myocardial infarction in conscious dogs at high and low risk of sudden deathJACC, 1990
- Carbon monoxide and lethal arrhythmias in conscious dogs with a healed myocardial infarctionAmerican Heart Journal, 1989
- Decreased heart rate variability and its association with increased mortality after acute myocardial infarctionThe American Journal of Cardiology, 1987
- Paradoxical Vasoconstriction Induced by Acetylcholine in Atherosclerotic Coronary ArteriesNew England Journal of Medicine, 1986
- β-Adrenergic Blockade for Survivors of Acute Myocardial InfarctionNew England Journal of Medicine, 1984
- The effects of psychological stress and vagal stimulation with morphine on vulnerability to ventricular fibrillation (VF) in the conscious dogAmerican Heart Journal, 1978
- Differing mechanisms for ventricular vulnerability during coronary artery occlusion and releaseAmerican Heart Journal, 1976
- The effect of vagus nerve stimulation upon vulnerability of the canine ventricle: role of sympathetic-parasympathetic interactions.Circulation, 1975
- Effect of autonomic neural influences on the cardiovascular changes induced by coronary occlusionAmerican Heart Journal, 1975
- Temporal dispersion of recovery of excitability in atrium and ventricle as a function of heart rateAmerican Heart Journal, 1966