Multiparametric Magnetic Resonance Imaging of the Prostate
Authors:
Open Access
- 1 September 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 52 (9) , 538-546
Abstract
Objectives: The aim of this study was to evaluate the repeatability of a region of interest (ROI) volume and mean apparent diffusion coefficient (ADC) in standard-of-care 3 T multiparametric magnetic resonance imaging (mpMRI) of the prostate obtained with the use of endorectal coil. Materials and Methods: This prospective study was Health Insurance Portability and Accountability Act compliant, with institutional review board approval and written informed consent. Men with confirmed or suspected treatment-naive prostate cancer scheduled for mpMRI were offered a repeat mpMRI within 2 weeks. Regions of interest corresponding to the whole prostate gland, the entire peripheral zone (PZ), normal PZ, and suspected tumor ROI (tROI) on axial T2-weighted, dynamic contrast-enhanced subtract, and ADC images were annotated and assessed using Prostate Imaging Reporting and Data System (PI-RADS) v2. Repeatability of the ROI volume for each of the analyzed image types and mean ROI ADC was summarized with repeatability coefficient (RC) and RC%. Results: A total of 189 subjects were approached to participate in the study. Of 40 patients that gave initial agreement, 15 men underwent 2 mpMRI examinations and completed the study. Peripheral zone tROIs were identified in 11 subjects. Tumor ROI volume was less than 0.5 mL in 8 of 11 subjects. PI-RADS categories were identical between baseline-repeat studies in 11/15 subjects and differed by 1 point in 4/15. Peripheral zone tROI volume RC (RC%) was 233 mm3 (71%) on axial T2-weighted, 422 mm3 (112%) on ADC, and 488 mm3 (119%) on dynamic contrast-enhanced subtract. Apparent diffusion coefficient ROI mean RC (RC%) were 447 × 10−6 mm−2/s (42%) in PZ tROI and 471 × 10−6 mm−2/s (30%) in normal PZ. Significant difference in repeatability of the tROI volume across series was observed (P < 0.005). The mean ADC RC% was lower than volume RC% for tROI ADC (P < 0.05). Conclusions: PI-RADS v2 overall assessment was highly repeatable. Multiparametric magnetic resonance imaging sequences differ in volume measurement repeatability. The mean tROI ADC is more repeatable compared with tROI volume in ADC. Repeatability of prostate ADC is comparable with that in other abdominal organs.Keywords
This publication has 42 references indexed in Scilit:
- The Case for Using the Repeatability Coefficient When Calculating Test–Retest ReliabilityPLOS ONE, 2013
- Evaluation of Diffusion-Weighted MR Imaging at Inclusion in an Active Surveillance Protocol for Low-Risk Prostate CancerInvestigative Radiology, 2013
- DCE and DW MRI in monitoring response to androgen deprivation therapy in patients with prostate cancer: A feasibility studyMagnetic Resonance in Medicine, 2011
- A pilot study of endorectal magnetic resonance imaging and magnetic resonance spectroscopic imaging changes with dutasteride in patients with low risk prostate cancerBJU International, 2011
- Diffusion-weighted magnetic resonance imaging for monitoring prostate cancer progression in patients managed by active surveillanceBritish Journal of Radiology, 2011
- A Critical Analysis of the Tumor Volume Threshold for Clinically Insignificant Prostate Cancer Using a Data Set of a Randomized Screening TrialJournal of Urology, 2011
- Reproducibility and correlation between quantitative and semiquantitative dynamic and intrinsic susceptibility‐weighted MRI parameters in the benign and malignant human prostateJournal of Magnetic Resonance Imaging, 2010
- Repeatability of echo-planar-based diffusion measurements of the human prostate at 3 TMagnetic Resonance Imaging, 2007
- Accuracy of In-Vivo Assessment of Prostatic Volume by MRI and Transrectal UltrasonographyJournal of Computer Assisted Tomography, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986