Double Input Capacitively Coupled Contactless Conductivity Detector with Phase Shift
Authors:
- 24 September 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (20) , 10065-10070
Abstract
A double input capacitively coupled contactless conductivity detector (DIC4D) device which gets higher sensitivity has been described in this paper. The detector consists of two input electrodes and one output electrode. When two alternating current (AC) voltages with the same amplitude and different phases are imposed on each input electrode, the equivalent resistance of the output electrode is reduced because of the interference of the two signals with different phase angles. For a capacitively coupled contactless conductivity detector (C4D), the ratio of the response of KCl solution to that of distilled water is 1.6. However, for DIC4D, the ratio is 1.55 at a phase difference of 0° and increases to 1.8 at the phase difference of 170°, respectively. For C4D, the response of KCl solution is a linear function of the logarithm of concentrations from 10–5 M to 10–2 M, and the slope is 5.58. However, the slope of the response increases to 7.13 in DIC4D, and the limit of detection (LOD) of DIC4D is estimated to be 5 × 10–8 M. The slope of the three-way DIC4D is increased to 69.78. A flow injection device is employed for the evaluation of the applicability of DIC4D with the same range, and good reproducibility is confirmed through flow injection of the same solution 10 times. The relative standard deviation (RSD) is 0.7%, which demonstrates a promising application to capillary electrophoresis (CE).Keywords
Funding Information
- National Natural Science Foundation of China (21177090, 21377089)
This publication has 41 references indexed in Scilit:
- Capacitively coupled contactless conductivity detection on microfluidic systems—ten years of developmentAnalytical Methods, 2011
- Application of a low impedance contactless conductometric detector for the determination of inorganic cations in capillary monolithic column chromatographyTalanta, 2011
- A simplified poly(dimethylsiloxane) capillary electrophoresis microchip integrated with a low‐noise contactless conductivity detectorElectrophoresis, 2011
- End-to-End Differential Contactless Conductivity Sensor for Microchip Capillary ElectrophoresisAnalytical Chemistry, 2010
- Analysis of electroplating baths by capillary electrophoresis with high voltage contactless conductivity detectionMeasurement Science and Technology, 2006
- Improved dual photometric-contactless conductometric detector for capillary electrophoresisAnalytica Chimica Acta, 2004
- Detection of Human Immunoglobulin in Microchip and Conventional Capillary Electrophoresis with Contactless Conductivity MeasurementsAnalytical Chemistry, 2004
- Dual photometric-contactless conductometric detector for capillary electrophoresisAnalytica Chimica Acta, 2001
- Capillary Electrophoresis and Contactless Conductivity Detection of Ions in Narrow Inner Diameter CapillariesAnalytical Chemistry, 1999
- Determination of cations and anions by capillary electrophoresis combined with suppressed conductivity detectionAnalytical Chemistry, 1993