Aliphatic Hydrocarbon Spectra by Helium Ionization Mass Spectrometry (HIMS) on a Modified Atmospheric-Pressure Source Designed for Electrospray Ionization
- 10 May 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 22 (8) , 1395-1402
Abstract
Chemical-ionization techniques that use metastable species to ionize analytes traditionally use a flat pin or a sharp solid needle onto which the high potential needed to generate the discharge plasma is applied. We report here that direct analysis of samples containing volatile and semivolatile compounds, including saturated and unsaturated aliphatic hydrocarbons, can be achieved on any electrospray-ionization mass spectrometer by passing helium though the sample delivery metal capillary held at a high potential. In the helium plasma ionization source (HPIS) described here, the typical helium flow required (about 20–30 mL/min), was significantly lower than that needed for other helium-ionization sources. By this procedure, positive ions were generated by nominal hydride ion removal from molecules emanating from heated saturated hydrocarbons as large as tetratetracontane (C44H90), at capillary voltages ranging from 2.0 to 4.0 kV. Unsaturated hydrocarbons, on the other hand, underwent facile protonation under much lower capillary voltages (0.9 to 2.0 kV). Although saturated and monounsaturated hydrocarbons bearing the same number of carbon atoms generate ions of the same m/z ratio, a gas-phase deuterium exchange method is described to ascertain the identity of these isomeric ions originating from either protonation or hydride abstraction mechanisms. Moreover, mass spectrometric results obtained by exposing unsaturated hydrocarbons to D2O vapor in an HPIS-MS instrument confirmed that the proton donor for ionization of unsaturated hydrocarbons is protonated water.Keywords
This publication has 29 references indexed in Scilit:
- A Combined Desorption Ionization by Charge Exchange (DICE) and Desorption Electrospray Ionization (DESI) Source for Mass SpectrometryJournal of the American Society for Mass Spectrometry, 2011
- Desorption ionization by charge exchange (DICE) for sample analysis under ambient conditions by mass spectrometryJournal of the American Society for Mass Spectrometry, 2010
- Ambient analysis of saturated hydrocarbons using discharge-induced oxidation in desorption electrospray ionizationJournal of the American Society for Mass Spectrometry, 2010
- Ambient desorption ionization mass spectrometryTrAC Trends in Analytical Chemistry, 2008
- Analysis of the Inhibition of the Ergosterol Pathway in Fungi Using the Atmospheric Solids Analysis Probe (ASAP) MethodJournal of the American Society for Mass Spectrometry, 2007
- Analysis of Solids, Liquids, and Biological Tissues Using Solids Probe Introduction at Atmospheric Pressure on Commercial LC/MS InstrumentsAnalytical Chemistry, 2005
- Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient ConditionsAnalytical Chemistry, 2005
- Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray IonizationScience, 2004
- Characterization of a glow discharge ion source for the mass spectrometric analysis of organic compoundsJournal of the American Society for Mass Spectrometry, 1994
- Glow discharge mass spectrometry of some organic compoundsInternational Journal of Mass Spectrometry and Ion Processes, 1989