Workload and usefulness of daily, centralized home monitoring for patients treated with CIEDs: results of the MoniC (Model Project Monitor Centre) prospective multicentre study
Authors:
Open Access
- 9 November 2012
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (2) , 219-226
Abstract
Automated, daily Home Monitoring (HM) of pacemaker and implantable cardioverter-defibrillator (ICD) patients can improve patient care. Yet, HM introduction to routine clinical practice is challenged by resource allocation for regular HM data review. We tested the feasibility, safety, workload, and clinical usefulness of a centralized HM model consisting of one monitor centre and nine satellite clinics. Having no knowledge about patients' clinical data, a telemonitoring nurse (TN) and a supporting physician at the monitor centre screened and filtered HM data in 62 pacemaker and 59 ICD patients from nine satellite clinics for over 1 year. Basic screening of arrhythmic and technical events required 25.7 min (TN) and 0.7 min (physician) per working day, normalized for 100 patients monitored. Communication of relevant events to satellite clinics per email or phone required additional 4.3 min (TN) and 0.4 min (physician). Telemonitoring nurse also screened for abnormal developments in longitudinal data trends weekly for 3 months after implantation, and then monthly; one patient session lasted 4.0 ± 2.9 min. To handle transmission-gap notifications, TN needed additional 2.8 min daily. Satellite clinics received 231.3 observations from the monitor centre per 100 patients/year, which prompted 86.3 patient contacts or intensive HM screening periods by the satellite clinic itself (37.3% response rate), 51.7 extra follow-up controls (22.3%), and 30.1 clinical interventions (13.0%). Centralized HM was feasible, reliable, safe, and clinically useful. Basic screening and communication of relevant arrhythmic and technical events required a total of 30 min (TN) and 1.1 min (physician) daily per 100 patients monitored.Keywords
This publication has 28 references indexed in Scilit:
- Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-UpCirculation, 2010
- Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisoryEuropean Heart Journal, 2010
- Remote monitoring of implantable devices: The European experienceHeart Rhythm, 2009
- Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillatorsEP Europace, 2009
- Analysis of 57,148 Transmissions by Remote Monitoring of Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 2009
- Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systemsJournal of Interventional Cardiac Electrophysiology, 2008
- Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trialEP Europace, 2008
- Automatic home monitoring of implantable cardioverter defibrillatorsEP Europace, 2008
- Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilizationEP Europace, 2008
- Detection of Atrial Fibrillation by Implanted Devices with Wireless Data Transmission CapabilityPacing and Clinical Electrophysiology, 2005