A Single Sacral-Mounted Inertial Measurement Unit to Estimate Peak Vertical Ground Reaction Force, Contact Time, and Flight Time in Running
Open Access
Abstract
Peak vertical ground reaction force (), contact time (), and flight time () are key variables of running biomechanics. The gold standard method (GSM) to measure these variables is a force plate. However, a force plate is not always at hand and not very portable overground. In such situation, the vertical acceleration signal recorded by an inertial measurement unit (IMU) might be used to estimate , , and . Hence, the first purpose of this study was to propose a method that used data recorded by a single sacral-mounted IMU (IMU method: IMUM) to estimate . The second aim of this study was to estimate and using the same IMU data. The vertical acceleration threshold of an already existing IMUM was modified to detect foot-strike and toe-off events instead of effective foot-strike and toe-off events. Thus, and estimations were obtained instead of effective contact and flight time estimations. One hundred runners ran at 9, 11, and 13 km/h. IMU data (208 Hz) and force data (200 Hz) were acquired by a sacral-mounted IMU and an instrumented treadmill, respectively. The errors obtained when comparing , , and estimated using the IMUM to , , and measured using the GSM were comparable to the errors obtained using previously published methods. In fact, a root mean square error (RMSE) of 0.15 BW (6%) was obtained for while a RMSE of 20 ms was reported for both and (8% and 18%, respectively). Moreover, even though small systematic biases of 0.07 BW for and 13 ms for and were reported, the RMSEs were smaller than the smallest real differences [: 0.28 BW (11%), : 32.0 ms (13%), and : 32.0 ms (30%)], indicating no clinically important difference between the GSM and IMUM. Therefore, these results support the use of the IMUM to estimate , , and for level treadmill runs at low running speeds, especially because an IMU has the advantage to be low-cost and portable and therefore seems very practical for coaches and healthcare professionals.
Keywords
Funding Information
- Innosuisse - Schweizerische Agentur für Innovationsförderung (35793.1 IP-LS)
This publication has 57 references indexed in Scilit:
- The use of a single inertial sensor to identify stride, step, and stance durations of running gaitJournal of Science and Medicine in Sport, 2010
- Detecting foot-to-ground contact from kinematic data in runningFootwear Science, 2009
- The landing–take-off asymmetry of human running is enhanced in old ageJournal of Experimental Biology, 2008
- Ambulatory measurement of 3D knee joint angleJournal of Biomechanics, 2008
- Old men running: mechanical work and elastic bounceProceedings Of The Royal Society B-Biological Sciences, 2007
- Bone contact forces on the distal tibia during the stance phase of runningJournal of Biomechanics, 2007
- The landing–take-off asymmetry in human runningJournal of Experimental Biology, 2006
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- The biomechanics of runningGait & Posture, 1998
- Stride Adjustments during a Running Approach toward a Force PlateResearch Quarterly for Exercise and Sport, 1996