Calculation of the renal perfusion and glomerular filtration rate from the renal impulse response obtained with MRI
Open Access
- 26 April 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (5) , 1017-1025
Abstract
The aim of this study was to assess the importance of deconvolution for the calculation of renal perfusion and glomerular filtration rate (GFR) on the basis of concentration–time curves as measured with perfusion MRI. Six rabbits were scanned dynamically after injection of a gadolinium chelate. Concentration–time curves were generated by manually drawing regions of interest in the aorta and the renal cortex. To remove the dependency on the arterial input function, a regularized structured total least‐squares deconvolution algorithm was used to calculate the renal impulse response. This curve was fitted by the sum of two gamma variate functions, corresponding to the passage of the contrast agent in the glomeruli and the proximal convoluted tubules. Tracer kinetics models were applied to these two functions to obtain the renal perfusion and GFR. For comparison, these two parameters were also calculated on the basis of the renal concentration–time curve before deconvolution. The renal perfusion values correlated well (r = 0.9, P = 0.014) with the values calculated by a validated upslope method. The GFR values correlated well (r = 0.9, P = 0.014) with the values obtained from the clearance of 51Cr‐EDTA. A comparison of the values obtained with and without deconvolution demonstrated the necessity of deconvolution. Magn Reson Med 51:1017–1025, 2004.Keywords
This publication has 33 references indexed in Scilit:
- Noninvasive Measurement of Absolute Renal Perfusion by Contrast Medium-Enhanced Magnetic Resonance ImagingInvestigative Radiology, 2003
- Quantification of renal perfusion abnormalities using an intravascular contrast agent (part 2): Results in animals and humans with renal artery stenosisMagnetic Resonance in Medicine, 2003
- Quantification of renal perfusion using an intravascular contrast agent (part 1): Results in a canine modelMagnetic Resonance in Medicine, 2003
- Automated quantitative evaluation of diseased and nondiseased renal transplants with MR renographyJournal of Magnetic Resonance Imaging, 2002
- Evaluation of four postprocessing methods for determination of cerebral blood volume and mean transit time by dynamic susceptibility contrast imagingMagnetic Resonance in Medicine, 2002
- ELECTRON BEAM COMPUTERIZED TOMOGRAPHY ASSESSMENT OF IN VIVO SINGLE KIDNEY GLOMERULAR FILTRATION RATE AND TUBULAR DYNAMICS DURING CHRONIC PARTIAL UNILATERAL URETERAL OBSTRUCTION IN THE PIGJournal of Urology, 2001
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Measurement of renal transit of gadopentetate dimeglumine with echo‐planar MR imagingJournal of Magnetic Resonance Imaging, 1994
- Gd-DOTAInvestigative Radiology, 1990
- Non-invasive measurement of renal blood flow with 99mTc DTP A: comparison with radiolabeled microspheresCardiovascular Research, 1987