Design and Performance Evaluation of a Linear Ion Trap Mass Analyzer Featuring Half Round Rod Electrodes
Authors:
- 10 March 2015
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 26 (5) , 734-740
Abstract
A novel linear ion trap mass analyzer featuring half round rod electrodes (HreLIT) has been built. It is mainly composed of two pairs of stainless steel electrodes which have a cross-section of half round rod and a pair of end electrodes. The HreLIT has a simple structure and so it could be assembled by hand with relatively high mechanical accuracy. The external dimension of HreLIT is 50 mm × 29.5 mm × 28 mm (length × width × height) and its internal volume is about 3.8 cm3. A home-made HreLIT mass spectrometer with three-stage vacuum system was built and the performance of HreLIT was characterized using reserpine solution and PPG standard solution. When the scan rate was 254 u/s, mass peak with FWHM of 0.14 u was achieved for ions with m/z 609, which corresponds to a mass resolution of 4350. The HreLIT was also operated at a low q value of 0.28 to extend its mass range. The experiment result showed a mass range of over 2800 u and the amplitude of radio frequency (rf) signal was only 1560 V (0-p). Three-stage tandem mass spectrometry was successfully performed in the HreLIT, and the collision-induced dissociation (CID) efficiencies of MS2 (CID of ions with m/z 609) and MS3 (CID of ions with m/z 448) were 78% and 59%, respectively. Graphical AbstractKeywords
This publication has 32 references indexed in Scilit:
- Synchronized Discharge Ionization for Analysis of Volatile Organic Compounds Using a Hand-Held Ion Trap Mass SpectrometerAnalytical Chemistry, 2012
- Evaluation of Front-End Higher Energy Collision-Induced Dissociation on a Benchtop Dual-Pressure Linear Ion Trap Mass Spectrometer for Shotgun ProteomicsAnalytical Chemistry, 2011
- Quantification of Human Uridine-Diphosphate Glucuronosyl Transferase 1A Isoforms in Liver, Intestine, and Kidney Using Nanobore Liquid Chromatography–Tandem Mass SpectrometryAnalytical Chemistry, 2011
- Ultrasensitive Characterization of Site-Specific Glycosylation of Affinity-Purified Haptoglobin from Lung Cancer Patient Plasma Using 10 μm i.d. Porous Layer Open Tubular Liquid Chromatography−Linear Ion Trap Collision-Induced Dissociation/Electron Transfer Dissociation Mass SpectrometryAnalytical Chemistry, 2011
- Quadrupole mass filters with added hexapole fieldsRapid Communications in Mass Spectrometry, 2010
- Handheld Miniature Ion Trap Mass SpectrometersAnalytical Chemistry, 2009
- Research Profiles: Miniaturized rectilinear ion trapAnalytical Chemistry, 2004
- Rectilinear Ion Trap: Concepts, Calculations, and Analytical Performance of a New Mass AnalyzerAnalytical Chemistry, 2004
- Influence of the 6th and 10th spatial harmonics on the peak shape of a quadrupole mass filter with round rodsRapid Communications in Mass Spectrometry, 2002
- High mass‐resolution using a quadrupole ion‐trap mass spectrometerRapid Communications in Mass Spectrometry, 1991